Comparison of contact and free beam laser endarterectomy.

نویسندگان

  • Y Baribeau
  • J Eugene
  • S L Firestein
  • M Hammer-Wilson
  • M W Berns
چکیده

Free beam laser endarterectomy (LE) and contact laser endarterectomy (CLE) were compared in 15 arteriosclerotic New Zealand white rabbits. The rabbits underwent balloon catheter trauma to the thoracoabdominal aorta and were fed a 2% cholesterol diet for 18 weeks. Thoracoabdominal exploration was performed under general anesthesia and multiple endarterectomies were performed in each rabbit. Atheromas were dissected from arteries with laser radiation and end points were welded in place with laser radiation. LEs (N = 8) were performed with argon ion radiation delivered through a 400 microns fiberoptic. Power was kept constant at 1 W and the average fluence was 97.5 +/- 6.6 J/cm2. CLEs were performed with conical sapphire probes powered by either argon ion radiation (N = 12) or Nd-YAG radiation (N = 10). Power used was 1 W to 4 W for each laser. Average argon ion fluence was 117.8 +/- 3.1 J/cm2 and average Nd-YAG fluence was 611.1 +/- 34.4 J/cm2. Following the operations, aortas were removed, fixed, serially sectioned, and stained. Microscopic study revealed welded end points with LE but not with CLE. There were no perforations with LE. There were 11/12 perforations with argon ion CLE and 8/10 perforations with Nd-YAG CLE. Free beam laser endarterectomy is superior to contact laser endarterectomy for experimental atheromas.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using of Broadened Asymmetric Waveguide Structure for 980nm Diode Laser

Laser diode beam divergence is the main parameter for beam shaping and fiber optic coupling. Increasing the waveguide layer thickness is the conventional method to decrease the beam divergence. In this paper, the broadened asymmetric waveguide is introduced to decrease the divergence without increasing the optical power. The asymmetric waveguide was used to shift the vertical optical field to n...

متن کامل

Nominal Hazard Zone in Medical Laser Centers

Control the laser beam hazards for class IIIB and IV laser is concluded: engineering and executive controls. In executive control, when laser beam enters to the free space, the controlled area must be identified to protect people and control the radiation exposure limits. Given the fact that the laser light of the laser is entering the environment, the identification of the area under control i...

متن کامل

Measuring the deposited energy from a non-ionizing laser beam in water by digital holographic interferometry

Digital Holographic interferometry is a powerful and widely used optical technique for accurate measurement of variations in physical quantities such as density, refractive index, and etc. In this study, an experimental digital holographic interferometry setup was designed and used to measure the amount of energy changes induced by absorption of radiation from a non-ionizing infrared laser beam...

متن کامل

Numerical Investigation of the Non-Uniformity of the Electric Field Distribution by Injection of Net Electron Charge in TE CO2 Laser

In this report, the distribution and deviation of electric field in the active medium of the TE CO2 laser has been investigated due to the injection of net electron charge beam as a plasma generator. Some parameters of system have been considered, such as density and mean-free-path of injected charge beam. The electric potential and electric field distribution have been simulated by solving the...

متن کامل

Ohmic Contact of Cu/Mo and Cu/Ti Thin Layers on Multi-Crystalline Silicon Substrates

Cu-Mo and Cu-Ti contact structures were fabricated on multi-crystalline silicon substrates to provide a low resistance ohmic contact. Deposition steps are done in an excellent vacuum chamber by means of electron beam evaporation and samples are then annealed for the realization of an efficient alloy layer. The effects of process parameters such as film thickness, annealing duration and temp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of surgical research

دوره 48 2  شماره 

صفحات  -

تاریخ انتشار 1990