Tapping Pilot Hole: Mechanical Analysis of Sheep Vertebra and the Artificial Bone Model.

نویسندگان

  • Patrícia Silva
  • Rodrigo César Rosa
  • Antonio Carlos Shimano
  • Francisco José Albuquerque de Paula
  • José Batista Volpon
  • Helton Luiz Aparecido Defino
چکیده

OBJECTIVE To determine the effect of pilot hole tapping, together with other variables such as pilot hole diameter, in relation to inner screw diameter and preparation method, on the insertion torque and pullout resistance of the screws used for anterior fixation of the cervical spine. METHOD Twenty polyurethane test bodies and 30 thoracic vertebrae (T1-T5) were tested. Four holes were drilled into each test body: two of them with a diameter of 2.0 mm and two with a diameter of 2.5 mm. The holes were drilled using a bit or probe, according to the experimental group. Each experimental group was divided into two equal subgroups, with and without pilot hole tapping. In all, there were eight experimental groups: four using polyurethane specimens and four using sheep vertebrae. Cortical screws of 3.5 mm in outer diameter and 14 mm in length were inserted into the pilot holes. The insertion torque was measured during screw implantation and mechanical pullout tests were then performed using an Emic(®) universal testing machine, with the Tesc 3.13 software, load cells of 1000 N, force application rate of 0.2 mm/min, preloading of 5 N and accommodation time of 10 seconds. The property evaluated in the mechanical tests was the maximum pullout force. RESULTS AND CONCLUSION Pilot hole tapping significantly decreased the insertion torque and pullout force of the screws in all the experimental groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Pilot Hole Tapping on Pullout Strength and Insertion Torque of Dual Core Pedicle Screws.

OBJECTIVE To evaluate the influence of pilot hole tapping on pullout resistance and insertion torque of pedicle screws with a conical core. METHODS Mechanical tests using a universal testing machine were performed on pedicle screws with a conical core that were inserted into pedicles in the fifth lumbar vertebra of calves. The insertion torque was measured using a torque meter with a capacity...

متن کامل

Biomechanical Evaluation of the Influence of Cervical Screws Tapping and Design

OBJECTIVE To assess if the screw design (self-drilling/self-tapping) and the pilot hole tapping could affect the insertion torque and screw pullout strength of the screw used in anterior fixation of the cervical spine. METHODS Forty self-tapping screws and 20 self-drilling screws were inserted into 10 models of artificial bone and 10 cervical vertebrae of sheep. The studied parameters were th...

متن کامل

Dynamic Modeling of a Robot Manipulator for Opening the Tap Hole of an Electric Arc Furnace

The electric arc furnace (EAF) is used to produce high quality steel from steel scraps. The EAF uses plasma arc to generate heat for melting scarp or direct reduced iron (DRI). The liquid metal should be drained from the tap hole. Manual tapping operation of the EAF in the hot environment around the furnace is a potentially dangerous and time consuming task for the workers. Therefore, it is ess...

متن کامل

Online Dimensional Controlling System for Drilling

The drilling is well known as one of the most common hole making processes in the industry.Due to close tolerance requirement for drilled holes in the most of work pieces, onlinecontrolling of the diameter of drilled holes seems to be necessary. In the current work, an onlinedimensional controlling system was developed for drilling process. Doing this, drilling processwas executed in different ...

متن کامل

Human versus sheep intervertebral disc mechanical and vertebral cortical bone strain properties

INTRODUCTION Obtaining human material for studies of the spine is difficult because of ethical and government regulatory restrictions. Animal models are increasingly being used for research studies of the spine [1], and the sheep lumbar intervertebral disc has been shown to have morphological [2] and biochemical [3] similarities to human lumbar discs. Sheep have been used as a large animal mode...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista brasileira de ortopedia

دوره 45 3  شماره 

صفحات  -

تاریخ انتشار 2010