چکیده

Endovascular abdominal aortic aneurysm (AAA) repair has been widely used for the treatment of AAA as a safe and efficient method, but endoleaks causing persistent expansion of aneurysm sac may cause aneurysmal rupture and death. Type 3 endoleak is rare but a predominant cause of late rupture. Type 3b endoleak can be misdiagnosed as type 2 endoleak, which is more frequent. Here we report two cases of type 3b endoleak mimicking type 2 endoleak, which were successfully treated by open surgery of partial explantation of the stent-graft and endoaneurysmal interposition graft replacement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Late Type 3b Endoleak with an Endurant Endograft

Endovascular stent grafting with different commercially available stent graft systems is widely applied for the treatment of abdominal aortic aneurysms with high success rates in the current era. Various types of endoleaks are potential complications of the procedure. They usually occur in the early period. In this report, we present type 3b endoleak occurring 14 months after a successful endov...

متن کامل

Late Sac Rupture due to a Type IV Endoleak after Previous Endovascular Aortic Aneurysm Repair: A Case Report

Type IV endoleaks have been identified as endoleaks of low flow, and rupture risk has been estimated to be minimal in literature. Therefore, conservative treatment has been recommended in most cases. We are presenting a rare case of late rupture due to type IV endoleak that was treated with open repair applying a novel surgical technique.

متن کامل

Atypical Presentation of a Type 2 Endoleak following Emergency Open Repair of a Ruptured Abdominal Aortic Aneurysm

BACKGROUND An endoleak is a common complication following EVAR. Specifically, a Type 2 endoleak occurs because of retrograde flow from lumbar vessels outside the endograft within the aneurysm sac. Even though it is common following EVAR, it has not been identified as a complication following open ruptured abdominal aortic aneurysm (AAA) repair. REPORT A 73-year-old male underwent open repair ...

متن کامل

A Case of Successful Coil Embolization for a Late-Onset Type Ia Endoleak after Endovascular Aneurysm Repair with the Chimney Technique

Juxtarenal aortic aneurysms (JRAAs) are challenging to treat by endovascular aneurysm repair (EVAR) procedures. The chimney technique with EVAR (Ch-EVAR) is one of the feasible and less invasive treatments for JRAAs. However, the main concern of Ch-EVAR is the potential risk of "gutters," which can lead to type Ia endoleak (EL). Most type Ia ELs after Ch-EVAR procedures occurred intraoperativel...

متن کامل

Late type III endoleak after thoracic endovascular aneurysm repair and previous infrarenal stent graft implantation – a case report and review of the literature

Thoracic endovascular aortic repair (TEVAR) effectively improved the results of thoracic aortic aneurysm treatment. TEVAR is a less invasive procedure that can be performed under local anesthesia with shorter hospital stay. The perioperative morbidity and mortality rates are lower for endovascular than open repair, but the rate of secondary interventions is higher for TEVAR. We report a case of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 33  شماره 

صفحات  -

تاریخ انتشار 2017