Reliability and concurrent validity of a novel method allowing for in-shoe measurement of navicular drop
نویسندگان
چکیده
BACKGROUND Increased navicular drop is associated with increased risk of lower extremity overuse injuries and foot orthoses are often prescribed to reduce navicular drop. For laboratory studies, transparent shoes may be used to monitor the effect of orthoses but no clinically feasible methods exist. We have developed a stretch-sensor that allows for in-shoe measurement of navicular drop but the reliability and validity is unknown. The purpose of this study was to investigate: 1) the reliability of the stretch-sensor for measuring navicular drop, and 2) the concurrent validity of the stretch-sensor compared to the static navicular drop test. METHODS Intra- and inter-rater reliability was tested on 27 participants walking on a treadmill on two separate days. The stretch-sensor was positioned 20 mm posterior to the tip of the medial malleolus and 20 mm posterior to the navicular tuberosity. The participants walked six minutes on the treadmill before navicular drop was measured. Reliability was quantified by the Intraclass Correlation Coefficient (ICC 2.1) and agreement was quantified by Limits of Agreement (LOA). To assess concurrent validity, static navicular drop was measured with the stretch-sensor and compared with static navicular drop measured with a ruler on 27 new participants. Linear regression was used to measure concurrent validity. RESULTS The reliability of the stretch-sensor was acceptable for barefoot measurement (intra- and inter-rater ICC: 0.76-0.84) but lower for in-shoe measurement (ICC: 0.65). There was a significant association between static navicular drop measured with the stretch-sensor compared with a ruler (r = 0.745, p < 0.001). CONCLUSION This study suggests that the stretch-sensor has acceptable reliability for dynamic barefoot measurement of navicular drop. Furthermore, the stretch-sensor shows concurrent validity compared with the static navicular drop test as performed by Brody. This new simple method may hold promise for both clinical assessment and research but more work is needed before the method can be recommended.
منابع مشابه
A Novel Method for Measuring In-Shoe Navicular Drop during Gait
Analysis of foot movement is essential in the treatment and prevention of foot-related disorders. Measuring the in-shoe foot movement during everyday activities, such as sports, has the potential to become an important diagnostic tool in clinical practice. The current paper describes the development of a thin, flexible and robust capacitive strain sensor for the in-shoe measurement of the navic...
متن کاملArch height change during sit-to-stand: an alternative for the navicular drop test
BACKGROUND A study was conducted to determine the reliability and validity of a new foot mobility assessment method that utilizes digital images to measure the change in dorsal arch height measured at 50% of the length of the foot during the Sit-to-Stand test. METHODS Two hundred - seventy five healthy participants participated in the study. The medial aspect of each foot was photographed wit...
متن کاملThe mutual effect of navicular drop and the type of foot covering on the contact forces of ankle and knee joints during running
Introduction: One of the best interventions in the field of reducing injury and improving performance is running shoes. Despite this, the research results show that achieving the desired result due to using shoes depends on paying attention to other influencing factors such as foot structure. Therefore, the present study was carried out with the aim of investigating the mutual effect of navicul...
متن کاملبررسی اعتبار و پایایی نسخه فارسی پرسشنامهی زندگی ارزشمند: مبتنی بر رویکرد تعهد و پذیرش
Introduction: One of the main concepts of Acceptance and Commitment Therapy (ACT) is the concept of the values of people’s lives that can play a significant role in creating a psychological flexibility. Aim of this study was to investigate the psychometric characteristics of Persian version of Valued Living Questionnaire (VLQ). Method: In this Correlation-Descriptive study, 369 Undergradua...
متن کاملThe Applicability, Concurrent Validity and Internal Consistency Reliability of the Persian Version of the National Institutes of Health Stroke Scale (NIHSS): Evidences for Gender Differences
Background: The National Institutes of Health Stroke Scale (NIHSS) can objectively quantify the severity of stroke. However no information is available about psychometric properties and it’s applicability in the Iranian population. Objectives: The present study purposed by utilization of this instrument for neurological deficits measurement due to stroke, to determine the internal cons...
متن کامل