Visual perception changes and optical stability after intracorneal ring segment implantation: comparison between 3 months and 1 year after surgery
نویسندگان
چکیده
PURPOSE To prospectively evaluate intracorneal ring segment (ICRS) implantation on quality of life (QoL) of patients with keratoconus changes and identify factors responsible. METHODS Sixty-nine eyes of 42 keratoconus patients were implanted with the Keraring (Mediphacos, Belo Horizonte, Brazil). Best corrected visual acuity (BCVA), refraction, and steep keratometry were analyzed 3 months and 1 year after surgery. All patients self-administered the National Eye Institute Refractive Error Quality of life instrument at 2 time points: after having worn best correction for at least 30 days since evaluation (mean 4 months after surgery) and 1 year after surgery. To analyze if the use of the appropriate correction at 1 year follow up had any impact on visual acuity and V-QoL, patients were divided into 2 groups: group A (appropriate correction) and B (not appropriate correction). RESULTS After 1 year, QoL changes related to scales 'clarity of vision', 'near vision', and 'far vision'. Keratometric values, sphere, and spherical equivalent did not differ significantly between 3 months and 1 year postoperative. Cylinder increase was statistically but not clinically significant. Binocular BCVA did not change 1 year after surgery in group A and showed a clinically significant impairment in group B. A year after surgery, 18 patients did not use correction suggested by a physician 3 months after surgery. QoL was not statistically different 1 year after surgery between group A and group B. CONCLUSION Our findings show that the way keratoconic patients see is difficult to analyze using only quantitative and 1-visit metrics. They highlight the importance of patients' self perception and performing longitudinal analysis to consider neural compensation to optical changes from surgery.
منابع مشابه
Effects of Intracorneal Ring Segment on Corneal Biomechanics in Keratoconic Eyes
Purpose: To evaluate the biomechanical changes of cornea after intracorneal ring segment (ICRS) implantation in keratoconic eyes Methods: In this study, 1 or 2 ICRS were inserted in 17 keratoconic eyes. Best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity (UCVA), refraction, and keratometry were evaluated preoperatively and 1 and 3 months after surgery. Corneal hysteresis (...
متن کاملIntracorneal ring segment implantation in corneas with post-laser in situ keratomileusis keratectasia.
PURPOSE To evaluate the refractive and aberrometric changes in corneas with post-LASIK keratectasia implanted with intracorneal ring segments (ICRS) during a 2-year follow-up. DESIGN Retrospective, consecutive case series. PARTICIPANTS Thirty-four eyes of 25 patients (age range, 20-59 years) with post-LASIK ectasia were included. Ectasia was diagnosed by slit-lamp appearance of corneal thin...
متن کاملVisual rehabilitation in moderate keratoconus: combined corneal wavefront-guided transepithelial photorefractive keratectomy and high-fluence accelerated corneal collagen cross-linking after intracorneal ring segment implantation
BACKGROUND To investigate the effects of combined corneal wavefront-guided transepithelial photorefractive keratectomy (tPRK) and accelerated corneal collagen cross-linking (CXL) after intracorneal ring segment (ICRS) implantation in patients with moderate keratoconus. METHODS Medical records of 23 eyes of 23 patients undergoing combined tPRK and CXL after ICRS implantation were retrospective...
متن کاملTreatment of visual problems after intracorneal ring implantation
PURPOSE To report the effect of wavefront-guided photorefractive keratectomy and corneal collagen cross-linking (CXL) on visual problems after Ferrara ring segment placement. MATERIALS AND METHODS A 32-year-old male patient was treated with a Ferrara ring segment for keratoconus. One year later, the ring was removed due to severe glare complaints. After 6 months, wavefront-guided photorefract...
متن کاملFerrara intracorneal ring segments for keratoconus.
PURPOSE To assess the outcome of Ferrara intracorneal ring segments for keratoconus. SETTING Private practice and university hospital, Porto Alegre, Brazil. METHODS In this retrospective noncomparative interventional case series, 51 keratoconus eyes of 47 patients that had Ferrara intracorneal ring segment implantation were reviewed. Uncorrected visual acuity (UCVA), best spectacle-correcte...
متن کامل