The transferability of a measurement protocol from one laboratory to another is an important feature of any mature, standardised protocol. The electron paramagnetic resonance (EPR)-tooth dosimetry technique that was developed in Scientific Center for Radiation Medicine, AMS, Ukraine (SCRM) for routine dosimetry of Chernobyl liquidators has demonstrated consistent results in several inter-laboratory measurement comparisons. Transferability to the EPR dosimetry laboratory at the National Institute of Standards and Technology (NIST) was examined. Several approaches were used to test the technique, including dose reconstruction of SCRM-NIST inter-comparison samples. The study has demonstrated full transferability of the technique and the possibility to reproduce results in a different laboratory environment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrospective dosimetry using fingernail in nuclear industries: A review paper

Generally, doses greater than 2Gy can produce acute biological effects in humans. For this reason, to measure and record the cumulative dose, especially in radiation users, the need for a personal dosimeter has been strongly felt by the researchers. The purpose of this study is to introduce retrospective dosimetric techniques, in particular the use of nails as a natural tool for determining cum...

متن کامل

EPR and OSL emergency dosimetry with teeth: A direct comparison of two techniques

The OSL dosimetry technique with teeth has been validated against the EPR dosimetry technique through a measurement comparison performed on the same teeth. The OSL reconstructed doses were found to be in agreement with corresponding EPR doses. Minimum measurable doses for the OSL technique were estimated to be in the range 0.9e1.5 Gy for measurements made within 24 h post-exposure if OSL signal...

متن کامل

Stability study of free radicals in 10 MeV electron beam irradiated quartz as an EPR dosimetry method

Many properties of a material, such as physical shape, crystalline or amorphous form, and particle size, may affect the quality of EPR response. The effects of mechanical treatment to a material such as grinding, crushing, and particle size on EPR signal were reported earlier [1, 9]. The EPR technique is a well known and well established method for dose measurement in several fields like radiat...

متن کامل

Human EPR Dosimetry at Low Accumulated Dose of Ionizing Radiation Human EPR Dosimetry at Low Accumulated Dose of Ionizing Radiation

A new method for tooth (enamel and dentine) and bone EPR dosimetry is proposed that enhances substantially the dosimetric sensitivity. The method is based on the nonstandard spectra registration mode (the second harmonic phase quadrature detection of absorption under rapid passage conditions). This method provides an apparent enhancement of the component ratio of radiation to a nonradiative bac...

متن کامل

EPR Dosimetry of Chernobyl Liquidators

The paper is devoted to review of development and application of EPR dosimetry with teeth in Ukraine. It deals with specific features of the EPR dosimetry protocol, which was developed and is practically used in SCRM for retrospective dosimetry of clean-up workers (liquidators). Extensive methodological research was conducted in SCRM in order to develop an original version of EPR dosimetric pro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 120 1-4  شماره 

صفحات  -

تاریخ انتشار 2006