2D and 3D CT Radiomics Features Prognostic Performance Comparison in Non-Small Cell Lung Cancer
نویسندگان
چکیده
OBJECTIVE To compare 2D and 3D radiomics features prognostic performance differences in CT images of non-small cell lung cancer (NSCLC). METHOD We enrolled 588 NSCLC patients from three independent cohorts. Two sets of 463 patients from two different institutes were used as the training cohort. The remaining cohort with 125 patients was set as the validation cohort. A total of 1014 radiomics features (507 2D features and 507 3D features correspondingly) were assessed. Based on the dichotomized survival data, 2D and 3D radiomics indicators were calculated for each patient by trained classifiers. We used the area under the receiver operating characteristic curve (AUC) to assess the prediction performance of trained classifiers (the support vector machine and logistic regression). Kaplan-Meier and Cox hazard survival analyses were also employed. Harrell's concordance index (C-Index) and Akaike's information criteria (AIC) were applied to assess the trained models. RESULTS Radiomics indicators were built and compared by AUCs. In the training cohort, 2D_AUC=0.653, 3D_AUC=0.671. In the validation cohort, 2D_AUC=0.755, 3D_AUC=0.663. Both 2D and 3D trained indicators achieved significant results (P<.05) in the Kaplan-Meier analysis and Cox regression. In the validation cohort, 2D Cox model had a C-Index=0.683 and AIC=789.047; 3D Cox model obtained a C-Index=0.632 and AIC=799.409. CONCLUSION Both 2D and 3D CT radiomics features have a certain prognostic ability in NSCLC, but 2D features showed better performance in our tests. Considering the cost of the radiomics features calculation, 2D features are more recommended for use in the current study.
منابع مشابه
Prognostic value of various metabolic parameters on pre-treatment 18-F-FDG PET/CT in patients with stage I-III non-small cell lung cancer
Background: the aim of this study was to investigate the prognostic value of 18Fluorine-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) parameters in both overall survival and progression-free survival in Stage I-III non-small cell lung cancer (NSCLC). Materials and Methods: In this retrospective study, 267 patients who were diagnosed as Stage I-III non-smal...
متن کاملSurvival prediction of non-small cell lung cancer patients using radiomics analyses of cone-beam CT images.
BACKGROUND AND PURPOSE In this study we investigated the interchangeability of planning CT and cone-beam CT (CBCT) extracted radiomic features. Furthermore, a previously described CT based prognostic radiomic signature for non-small cell lung cancer (NSCLC) patients using CBCT based features was validated. MATERIAL AND METHODS One training dataset of 132 and two validation datasets of 62 and ...
متن کاملRadiomics-based Prognosis Analysis for Non-Small Cell Lung Cancer
Radiomics characterizes tumor phenotypes by extracting large numbers of quantitative features from radiological images. Radiomic features have been shown to provide prognostic value in predicting clinical outcomes in several studies. However, several challenges including feature redundancy, unbalanced data, and small sample sizes have led to relatively low predictive accuracy. In this study, we...
متن کاملThe Comparison 2D and 3D Treatment Planning in Breast Cancer Radiotherapy with Emphasis on Dose Homogeneity and Lung Dose
Introduction: Breast conserving radiotherapy is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is usually used for this purpose. This technique is performed using 2D or 3D treatment planning systems. The aim of this study was to compare 2D treatment planning with 3D treatment planning in tangential irradiation in breast conse...
متن کاملComparison of PET/CT and CT-based tumor delineation and its effects on the radiation treatment planning for non-small cell lung cancer
Introduction: Tumor volume delineation is the most important step in the radiation treatment planning. In this study the impact of PET/CT data on the tumor delineation precision of non-small cell lung cancer (NSCLC) was investigated. Methods: PET/CT images of 20 patients with primary NSCLC were obtained and imported to the treatment planning system for im...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2017