Optimization of Peripheral Vascular Sizing with Conductance Guidewire: Theory and Experiment

نویسندگان

  • Hyo Won Choi
  • Zachary C. Berwick
  • Matthew S. Sulkin
  • Christopher D. Owens
  • Ghassan S. Kassab
چکیده

Although the clinical range of interventions for coronary arteries is about 2 to 5 mm, the range of diameters of peripheral vasculature is significantly larger (about 10 mm for human iliac artery). When the vessel diameter is increased, the spacing between excitation electrodes on a conductance sizing device must also increase to accommodate the greater range of vessel diameters. The increase in the excitation electrodes distance, however, causes higher parallel conductance or current losses outside of artery lumen. We have previously shown that the conductance catheter/guidewire excitation electrode distances affects the measurement accuracy for the peripheral artery lumen sizing. Here, we propose a simple solution that varies the detection electrode distances to compensate for parallel conductance losses. Computational models were constructed to simulate the conductance guidewire with various electrodes spacing combinations over a range of peripheral artery lumen diameters and surrounding tissue electrical conductivities. The results demonstrate that the measurement accuracy may be significantly improved by increased detection spacing. Specifically, an optimally configured detection/excitation spacing (i.e., 5-5-5 or an equidistant electrode interval with a detection-to-excitation spacing ratio of 0.3) was shown to accurately predict the lumen diameter (i.e., -10% < error < 10%) over a broad range of peripheral artery dimensions (4 mm < diameter < 10 mm). The computational results were substantiated with both ex-vivo and in-vivo measurements of peripheral arteries. The present results support the accuracy of the conductance technique for measurement of peripheral reference vessel diameter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does Heart Affect Peripheral Vascular Resistance Following Myocardial Ischemia and Reperfusion?

Objective(s) The aim of this study was to investigate the overall effect of cardiac vasoactive factors during coronary occlusion and reperfusion on peripheral vascular tone, using a sequential isolated rabbit heart-ear perfusion model. Materials and Methods Isolated ears were perfused with the effluent of isolated hearts subjected to ischemia (30 min) and reperfusion (180 min, n=6). The comp...

متن کامل

Optimal Placement and Sizing of DG in Distributed Network using NSGA-II based on Cold-Standby Strategy

Abstract: in this Paper, Optimal placement and sizing of DGs is considered as an engineering optimization problem. Due to integration and influence of DGs in distributed networks, optimal location and sizing of them are done based on objective functions such as: voltage profile improvement, power loss reduction, reliability improvement, restraining the increase of power plant, etc. These goals ...

متن کامل

SIZING OPTIMIZATION OF TRUSS STRUCTURES WITH NEWTON META-HEURISTIC ALGORITHM

This study is devoted to discrete sizing optimization of truss structures employing an efficient discrete evolutionary meta-heuristic algorithm which uses the Newton gradient-based method as its updating scheme and it is named here as Newton Meta-heuristic Algorithm (NMA). In order to enable the NMA population-based meta-heuristic to effectively explore the discrete design space, a term contain...

متن کامل

Optimal Placement and Sizing of Distributed Generation Via an Improved Nondominated Sorting Genetic Algorithm II

The use of distributed generation units in distribution networks has attracted the attention of network managers due to its great benefits. In this research, the location and determination of the capacity of distributed generation (DG) units for different purposes has been studied simultaneously. The multi-objective functions in the optimization model are reducing system line losses; reducing v...

متن کامل

Optimal Locating and Sizing of Unified Power Quality Conditioner- phase Angle Control for Reactive Power Compensation in Radial Distribution Network with Wind Generation

In this article, a multi-objective planning is demonstrated for reactive power compensation in radial distribution networks with wind generation via unified power quality conditioner (UPQC). UPQC model, based on phase angle control (PAC), is used. In presented method, optimal locating of UPQC-PAC is done by simultaneous minimizing of objective functions such as: grid power loss, percentage of n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017