Massive bleeding despite tourniquet inflation in total knee replacement patient with a femoro-popliteal artery bypass graft
نویسندگان
چکیده
Corresponding author: Yun Hee Lim, M.D., Department of Anesthesiology and Pain Medicine, Sanggye Paik Hospital, Sanggye 7-dong, Nowongu, Seoul 139-707, Korea. Tel: 82-2-950-1173, Fax: 82-2-950-1323, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http:// creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. CC A tourniquet is used frequently in orthopedic surgeries, including total knee replacement, to reduce bleeding and enhance the visual field during surgery. Herein, we present a case with massive bleeding that occurred during a total knee replacement that had administered a tourniquet with adequate pressure. A 65-year-old man presented to the orthopaedic clinic for right total knee replacement due to osteoarthritis. The patient had right lower limb artery obstruction and a history of a right femoro-popliteal artery bypass graft 7 years prior to his visit. He was 169 cm tall weighing 68 kg. The patient had no other specific medical history, and no abnormal finding was covered on the preoperative examination. When the patient arrived at the operating room, his blood pressure was 150/90 mmHg. We provided propofol 120 mg and rocuronium 50 mg followed by induction with sevoflurane and 1 : 1 of oxygen and N2O. An inflation tourniquet with a pressure of 300 mmHg was applied to the right thigh. While the surgeon was making the skin incision to expose the joint, unpredicted massive bleeding occurred. Just before the tourniquet was applied, the patient’s blood pressure was 95/65 mmHg, and right after the tourniquet was inflated, it was 130/80 mmHg. Based on the assumption of a tourniquet function error, we applied a new tourniquet with 300 mmHg of pressure on the right thigh. However, the bleeding continued even when we the raised pressure up to 400 mmHg. The bleeding decreased considerably when we deflated the cuff. Furthermore, with ultrasonographic guidance, we found that the femoral artery flow was not blocked by the tourniquet; therefore, the surgeon proceeded with the surgery without use of a tourniquet. During the surgery, 1,200 ml of crystalloid solution, 500 ml of colloid solution and packed RBC 4 units were administered and the estimated blood loss was 2,500 ml. Upon searching for the cause of the unpredicted bleeding, we examined the blood flow of the right femoropopliteal artery bypass graft with ultrasonography 6 months later. It showed that both the femoro-popliteal artery bypass graft with or without 350 mmHg of tourniquet pressure had good blood flow (Fig. 1). A tourniquet is frequently used in total knee joint replacement surgeries to block the vascular flow of the limb during surgery. However, complications such as thigh pain, nerve injury, compartment syndrome, and nonalignment of the patella as well as systemic complications such as deep venous thrombosis, hypertension, and arrhythmia may occur. Therefore, it is important to maintain an adequate pressure and duration while using a tourniquet. There is no absolute limit on the pressure and duration when using a tourniquet, but Flatt [1] reported 2 hours is an adequate time if the patient has no hemodynamic problems. Horlocker et al. [2] reported 300 mmHg for the tourniquet pressure as being adequate for the lower limb. In this case, bleeding continued with an initial tourniquet pressure of 300 mmHg and even continued after we applied 400 mmHg of pressure. The use of the tourniquet instead increased the blood flow in our case. It is believed that the use of the tourniquet was unable to block the graft artery flow but collapsed the venous flow, which resulted in the
منابع مشابه
A Comparison of Interposition and Femoropopliteal Bypass Grafts in the Management of Popliteal Artery Trauma
Background: Peripheral vascular injury associated with lower limb trauma is a well-known emergency. The experience for the management of popliteal artery trauma have mainly come from managing the traumas of military personnels during Iran-Iraq war. The present study compared the effects of two currently-used surgical techniques in the management of popliteal trauma, namley femoropopliteal bypas...
متن کاملEndograft connector technique to treat popliteal artery aneurysm in a morbid obese patient.
Surgical repair of popliteal artery aneurysm in morbid obese patients poses additional challenges. We report a morbid obese patient who had a 59 mm right popliteal artery aneurysm which was successfully treated with the endograft connector technique. This technique was used to perform the distal anastomosis of the below-knee femoro-popliteal bypass. A 10 mm Dacron graft was used as a main graft...
متن کاملComparisons between prosthetic vascular graft and saphenous vein graft in femoro-popliteal bypass
PURPOSE Infrainguinalfemoropopliteal bypass (IFPB) is recommended to peripheral arterial disease (PAD) with a long occlusion of the superficial femoral artery (SFA). The aims of our study were to determine the patency of graft materials, and identify the risk factors of graft failure. METHODS From January 1995 to April 2011, we had performed 380 IFPBs in 351 patients, including 302 femoro-abo...
متن کاملFemoro-Supragenicular Popliteal Bypass with a Bridging Stent Graft in a Diffusely Diseased Distal Target Popliteal Artery: Alternative to Below-Knee Popliteal Polytetrafluoroethylene Bypass
Background Lesions in distal target arteries hinder surgical bypass procedures in patients with peripheral arterial occlusive disease. Methods Between April 2012 and October 2015, 16 patients (18 limbs) with lifestyle-limiting claudication (n=12) or chronic critical limb ischemia (n=6) underwent femoral-above-knee (AK) polytetrafluoroethylene (PTFE) bypass grafts with a bridging stent graft p...
متن کاملPTFE bypass to below-knee arteries: distal vein collar or not? A prospective randomised multicentre study.
BACKGROUND Patency and limb salvage after synthetic bypass to the arteries below-knee are inferior to that which can be achieved with autologous vein. Use of a vein collar at the distal anastomosis has been suggested to improve patency and limb salvage, a problem that is analysed in this randomised clinical study. METHODS Patients with critical limb ischaemia undergoing polytetrafluoroethylen...
متن کامل