Patient skin dose measurements using a cable free system MOSFETs based in fluoroscopically guided percutaneous vertebroplasty, percutaneous disc decompression, radiofrequency medial branch neurolysis, and endovascular critical limb ischemia

نویسندگان

  • Maria D. Falco
  • Salvatore Masala
  • Matteo Stefanini
  • Roberto Fiori
  • Roberto Gandini
  • Paolo Bagalà
  • Daniele Morosetti
  • Eros Calabria
  • Alessia Tonnetti
  • Gianluca Verona‐Rinati
  • Riccardo Santoni
  • Giovanni Simonetti
چکیده

The purpose of this work has been to dosimetrically investigate four fluoroscopically guided interventions: the percutaneous vertebroplasty (PVP), the percutaneous disc decompression (PDD), the radiofrequency medial branch neurolysis (RF) (hereafter named spine procedures), and the endovascular treatment for the critical limb ischemia (CLI). The X-ray equipment used was a Philips Integris Allura Xper FD20 imaging system provided with a dose-area product (DAP) meter. The parameters investigated were: maximum skin dose (MSD), air kerma (Ka,r), DAP, and fluoroscopy time (FT). In order to measure the maximum skin dose, we employed a system based on MOSFET detectors. Before using the system on patients, a calibration factor Fc and correction factors for energy (CkV) and field size (CFD) dependence were determined. Ka,r, DAP, and FT were extrapolated from the X-ray equipment. The analysis was carried out on 40 patients, 10 for each procedure. The average fluoroscopy time and DAP values were compared with the reference levels (RLs) proposed in literature. Finally, the correlations between MSD, FT, Ka,r, and DAP values, as well as between DAP and FT values, were studied in terms of Pearson's product-moment coefficients for spine procedures only. An Fc value of 0.20 and a very low dependence of CFD on field size were found. A third-order polynomial function was chosen for CkV. The mean values of MSD ranged from 2.3 to 10.8cGy for CLI and PVP, respectively. For these procedures, the DAP and FT values were within the proposed RL values. The statistical analysis showed little correlation between the investigated parameters. The interventional procedures investigated were found to be both safe with regard to deterministic effects and optimized for stochastic ones. In the spine procedures, the observed correlations indicated that the estimation of MSD from Ka,r or DAP was not accurate and a direct measure of MSD is therefore recommended.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluoroscopically Guided C2 Percutaneous Vertebroplasty: A Surgical Technique Note on an Anterior Ascending Approach.

BACKGROUND C2 vertebroplasty is more challenging than transpedicular percutaneous vertebroplasty in the thoracic and lumbar spine. OBJECTIVE We report an anterior ascending approach for C2 percutaneous vertebroplasty to avoid potential injury to vital structures surrounding the C2 vertebra. STUDY DESIGN A technique note with 5 consecutive cases. SETTING Neurosurgery department of a univer...

متن کامل

Critical Upper Limb Ischemia Due to Brachial Tourniquet in Misdiagnosed Thoracic Outlet Syndrome after Carpal Tunnel Decompression: A Case Report

We present the case of a 68-year-old woman, referred to our department for critical upper limb ischemia, which had occurred a few days after homolateral surgical ligamentotomy for carpal tunnel syndrome, diagnosed and confirmed by electromyography, and performed with a brachial tourniquet. The patient was later admitted for subsequent progressive necrosis of the first three fingers of the left ...

متن کامل

Ultrasound-guided Percutaneous Medial Pinning of Pediatric Supracondylar Humeral Fractures to Avoid Ulnar Nerve Injury.

Background:  Medial pinning is one of the most controversial aspects of the surgical treatment of supracondylar fractures (SHF) owing to the risk of ulnar nerve injury.  Aim: To evaluate the safety and usefulness of medial pinning for SHF using ultrasound imaging for ulnar nerve visualization.   Methods: Fifteen children, with a mean age of 60 months, with displaced SHF were treated with a cros...

متن کامل

درمان هرنیاسیون دیسک کمری با لیزر در بیمارستان امام خمینی (78-75)

Low back pain is among the most frequent medical complaints and a major public health problem. 1.7 percent of cases are caused by herniated disc, 20 percent of which require interventional treatment. Percutaneous laser disc decompression (P.L.DD) can be considered as an effective therapeutic alternative in certain cases. Materials and Methods: To determine the efficacy of this method in Iran i...

متن کامل

Percutaneous disc decompression for the treatment of chronic atypical cervical discogenic pain.

Percutaneous disc decompression with the radiofrequency coblation technique has been described to treat contained, symptomatic lumbar disc herniations. In symptomatic cervical disc herniations it has been used very selectively. We report a 42-year-old female with cervical disc pathology, predominantly at C6/C7, treated with percutaneous disc decompression using coblation technology. Her complai...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -