Influence of breast characteristics in myocardial scintigraphy through the Monte Carlo method.
نویسندگان
چکیده
BACKGROUND By reducing the specificity associated with loss of information, the influence of attenuation of the breasts is very important in myocardial perfusion studies. However, although several studies have been conducted over the past years, little has been developed to determine accurately the influence of the characteristics of the breasts on the quality of myocardial scintigraphy, avoiding additional exposure to radiation. OBJECTIVE The purpose of this study is to quantify the attenuation of photons by the breasts, in myocardial perfusion studies with (99m)Tc according to different sizes and compositions. METHODS Each breast was assumed to be a cube composed of fibroglandular and adipose tissue. The data related to (99m)Tc photons were analyzed in a Monte Carlo model. We varied the thickness and composition of breasts and analyzed the interference in attenuation. The EGS 4 software was used in the simulations. RESULTS Setting the thickness of a breast, the variation of its composition causes a maximum increase of 2.3% in the number of photons attenuated. By contrast, maintaining a fixed composition of breast tissue, the difference in photon attenuation was 45.0%, averaging 6.0% for each additional centimeter in the breast thickness. CONCLUSION Monte Carlo simulation showed that the influence of the thickness of the breasts in the attenuation of photons in myocardial scintigraphy with (99m)Tc is much greater than the influence of their compositions.
منابع مشابه
Evaluation of glandular dose in mammography in the presence of breast cyst using Monte Carlo simulation
Introduction: Average glandular dose (AGD), entrance skin air kerma (ESAK) and normalized glandular dose (DgN) are the main dosimetric quantities in mammography. In this study, DgN is evaluated in the presence of breast cyst, which is a common disease among women and the influence of size, number and location of the cysts on the DgN is investigated. Materials and Meth...
متن کاملImpact of Silicone gel breast prosthesis on photon beam therapy of recurrence carcinoma post mastectomy
AbstractIntroduction Silicone gel breast implants are used for breast reconstruction post mastectomy. In the event of cancer recurrence, the radiation oncologists are forced to irradiate through the prosthesis device. Due to prosthesis higher atomic number dose perturbations occur during treatment. This study determined the influence of silicone gel thickness on the photon beam distribution. Ma...
متن کاملEvaluation of the dose and flux of secondary particles in the lung tissue in breast proton therapy using the Monte Carlo simulation code
Unlike proton therapy, conventional radiation therapy directs X-rays not only at the tumor but also unavoidably at nearby healthy tissue. Protons deliver radiation to tumor tissue while the healthy structures will be spared during proton therapy. When protons travel through matter, secondary particles like neutrons and photons are produced. It is believed that the secondary dose can lead to sec...
متن کاملDetermination of the Energy Windows for the Triple Energy Window Scatter Correction Method in Gadolinium-159 Single Photon Emission Computed Tomography Using Monte Carlo Simulation
Introduction: In radionuclide imaging, object scatter is one of the major factors leading to image quality degradation. Therefore, the correction of scattered photons might have a great impact on improving the image quality. Regarding this, the present study aimed to determine the main and sub-energy windows for triple energy window (TEW) scatter correction method usin...
متن کاملDosimetric characteristics of 137Cs sources used in after loading Selectron system by Monte Carlo method
Background: For an effective treatment planning in brachytherapy, it is necessary to know the accurate source dosimetric information such as air kerma strength, exposure rate constant, dose rate constant and redial dose distribution. The usual method to determine these factors is thermo luminescent dosimeter (TLD) dosimetry. Nowadays, another more accurate method is known to be the Monte Carlo ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de cardiologia
دوره 96 1 شماره
صفحات -
تاریخ انتشار 2011