The biomechanical properties of the cornea and anterior segment parameters

نویسندگان

  • Ho Sik Hwang
  • Seh Kwang Park
  • Man Soo Kim
چکیده

BACKGROUND To investigate the biomechanical properties of the cornea measured with the Ocular Response Analyzer (ORA) and their association with the anterior segment parameters representing the geometric dimensions including the corneal volume and anterior chamber volume. METHODS A retrospective review of 1020 patients who visited the BGN Eye Clinic was done. The mean radius of the corneal curvature, corneal astigmatism, corneal volume, anterior chamber depth, and anterior chamber volume were measured with an anterior segment tomographer. The central corneal thickness (CCT) was measured with an ultrasonic pachymeter. The corneal diameter was measured with an Orbscan as White to White. Cornea hysteresis (CH), corneal resistance factor (CRF), Goldmann correlated intraocular pressure (IOPg), and cornea-compensated IOP (IOPcc) were measured with an ORA. Multiple linear regression models were constructed with CH and CRF as the dependent variables and age, gender, and the anterior segment parameters as the covariates. RESULTS 958 eyes from 958 patients (mean age 26.7 years; male 43.4%) were included in this study after excluding some eyes according to the exclusion criteria. The mean CH and CRF were 10.1 and 9.9 mmHg, respectively. The mean IOPg and IOPcc were 14.8 and 15.8 mmHg. The multivariate analysis showed that CH was negatively associated with the mean radius of the cornea curvature (regression coefficient = -0.481, p = 0.023) and positively associated with CCT (regression coefficient = 0.015, p < 0.001) and corneal volume (regression coefficient =0.059, p = 0.014). The association between CH and the corneal diameter, anterior chamber depth, and anterior chamber volume were not statistically significant. The evaluation of CRF showed that CRF was negatively associated with the mean radius of the cornea curvature (regression coefficient = -0.540, p = 0.013), and positively associated with CCT (β = 0.026, p < 0.001). The association between CRF and the corneal diameter, corneal volume, anterior chamber depth, and anterior chamber volume were not statistically significant. CONCLUSION The CH was shown to be positively associated with the corneal volume and the association between CH and the anterior chamber volume were not significant. The associations of CRF with the corneal volume or anterior chamber volume were not significant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anterior-segment morphology and corneal biomechanical characteristics in pigmentary glaucoma

PURPOSE The aim of the study reported here was to evaluate characteristics of the anterior-segment via anterior-segment optical coherence tomography (AS-OCT) and corneal biomechanical properties using an ocular response analyzer and their changes by peripheral laser iridotomy (PI) in patients with pigmentary glaucoma (PG). MATERIALS AND METHODS Seventeen eyes with PG were included consecutive...

متن کامل

Analysis of Thin Femtosecond Flaps with Anterior Segment Optical Coherence Tomography

Greater corneal biomechanical stability has been demonstrated following photorefractive keratectomy (PRK) compared with traditional microkeratome laser-assisted in situ keratomileusis (LASIK). Thin LASIK flaps exhibit biomechanical properties similar to PRK but with the advantage of no haze formation or pain. These findings suggest that thin flaps created with consistent thickness across the co...

متن کامل

Biomechanical Measurement of Rabbit Cornea by a Modified Scheimpflug Device

Purpose. To explore the probability and variation in biomechanical measurements of rabbit cornea by a modified Scheimpflug device. Methods. A modified Scheimpflug device was developed by imaging anterior segment of the model imitating the intact eye at various posterior pressures. The eight isolated rabbit corneas were mounted on the Barron artificial chamber and images of the anterior segment ...

متن کامل

Constructal approach to bio-engineering: the ocular anterior chamber temperature

The aim of this work was to analyse the pressure inside the eyes anterior chamber, namedintraocular pressure (IOP), in relation to the biomechanical properties of corneas. The approach used was based on the constructal law, recently introduced in vision analysis. Results were expressed as the relation between the temperature of the ocular anterior chamber and the biomechanical properties of the...

متن کامل

Numerical Analysis of the Thermal Interaction of Cell Phone Radiation with Human Eye Tissues

Introduction: The present study aimed to present a numerical analysis of the penetration depth,  specific absorption rate (SAR), and temperature rise in various eye tissues with varying distance between radiation source and exposed human eye tissues (i.e., cornea, posterior chamber, anterior chamber, lens, sclera, vitreous humor, and iris) at frequencies of 900 and1800 MHz. Materials and Method...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2013