Novel Landmark for Cervical Pedicle Screw Insertion Point from Computed Tomography-Based Study
نویسندگان
چکیده
STUDY DESIGN Cross-sectional study. PURPOSE The purpose of this study was to evaluate a novel landmark for the cervical pedicle screw insertion point. OVERVIEW OF LITERATURE To improve the accuracy of pedicle screw placement, several studies have employed the lateral mass, lateral vertical notch, and/or inferior articular process as landmarks; however, we often encounter patients in whom we cannot identify accurate insertion points for pedicle screws using these landmarks because of degenerative changes in the facet joints. The superomedial edge of the lamina is less affected by degenerative changes, and we hypothesized that it could be a new landmark for identifying an accurate cervical pedicle screw insertion point. METHODS A total of 327 consecutive patients, who had undergone neck computed tomographic scanning for determination of neck disease in our institute, were included in the study. At first, the line was drawn parallel to the superior border of the pedicle in the sagittal plane and parallel to the vertical body in the coronal plane. The line was moved downward in 1-mm increments to the inferior border of the pedicle. We determined whether the line passing through the superomedial edge of the lamina (termed the "N-line") was located between the superior and inferior borders of the pedicle in the sagittal plane. RESULTS The percentages of N-lines located between the superior and inferior borders of the pedicle were 100% at C3, 100% at C4, 99% at C5, 96% at C6, and 97% at C7. The lower cervical spine has the higher N-line location. CONCLUSIONS The N-line was frequently located at the level of the pedicle of each cervical spine in the sagittal plane. The superomedial edge of the lamina could be a new landmark for the insertion point of the cervical pedicle screw.
منابع مشابه
In vitro study of accuracy of subaxial cervical pedicle screw insertion using calipers based on the gravity line
OBJECT There is a high probability of iatrogenic perforation of the vertebral pedicle wall during the application of subaxial cervical pedicle screw (CPS). The goal of this study was to evaluate the accuracy of CPS insertion at C3-C7 in vitro using novel calipers based on the gravity line. METHODS Nine cadaveric cervical spines underwent computed tomography scanning and preoperative design. A...
متن کاملCervical Pedicle Screw Fixation: Anatomic Feasibility of Pedicle Morphology and Radiologic Evaluation of the Anatomical Measurements
STUDY DESIGN All parameters were measured manually and with a computed tomography (CT) scanner. For the manual measurements, a Vernier scale instrument was used. PURPOSE This study evaluates quantitatively pedicles of middle and lower cervical spine (C3 to C7) and to evaluate the possibilities of using these structures as anchors in posterior cervical fusion. OVERVIEW OF LITERATURE Pedicle ...
متن کاملMorphometric evaluation of subaxial cervical spine using multi-detector computerized tomography (MD-CT) scan: the consideration for cervical pedicle screws fixation
BACKGROUND Cervical pedicle screw (CPS) insertion is a technically demanding procedure. The quantitative understanding of cervical pedicle morphology, especially the narrowest part of cervical pedicle or isthmus, would minimize the risk of catastrophic damage to surrounding neurovascular structures and improve surgical outcome. The aim of this study was to investigate morphology and quantify co...
متن کاملA Novel Patient-Specific Drill Guide Template for Pedicle Screw Insertion into the Subaxial Cervical Spine Utilizing Stereolithographic Modelling: An In Vitro Study
STUDY DESIGN Cadaveric study. PURPOSE The purpose of this study was to assess the accuracy and feasibility of cervical pedicle screw (CPS) insertion into the subaxial cervical spine placed using a patient-specific drill guide template constructed from a stereolithographic model. OVERVIEW OF LITERATURE CPS fixation is an invaluable tool for posterior cervical fixation because of its biomecha...
متن کاملCervical Pedicle Screw Insertion Using the Technique with Direct Exposure of the Pedicle by Laminoforaminotomy
OBJECTIVE To present the accuracy and safety of cervical pedicle screw insertion using the technique with direct exposure of the pedicle by laminoforaminotomy. METHODS We retrospectively reviewed 12 consecutive patients. A total of 104 subaxial cervical pedicle screws in 12 patients had been inserted. We also assessed the clinical and radiological outcomes and analyzed the direction and grade...
متن کامل