Improved monochromatic imaging spectrometer.

نویسندگان

  • Michael R Webb
  • Gary M Hieftje
چکیده

Distortion inherent to a previously described system for acquisition of two-dimensional monochromatic spatial images is described. A solution is offered in the form of an improved instrument. The system uses a Czerny-Turner monochromator for spectral discrimination and a charge-coupled device (CCD) as the detector. A second Czerny-Turner monochromator, with identical dimensions, is added to correct the distortion, albeit with a slight loss in spatial resolution. With the earlier uncorrected arrangement, spatial resolution was on the order of 0.1 mm vertically and 0.3 mm horizontally, with a magnification of 0.52. With the same magnification, the new, corrected system offers spatial resolution of 0.1 mm vertically and 0.4 mm horizontally.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kα Cold-Target Imaging and Preheat Measurement Using a Pinhole-Array X-Ray Spectrometer

182 LLE Review, Volume 75 Two-dimensional (2-D) monochromatic imaging of laser-imploded targets1–6 is useful for diagnosing target compression and stability. Here we present a simple method for such imaging, using an array of about 300 pinholes placed in front of a flat-crystal x-ray spectrometer. The main advantage of this method (in addition to its simplicity) is the ability to simultaneously...

متن کامل

Normal-incidence efficiencies of multilayer-coated laminar gratings for the extreme-ultraviolet imaging spectrometer on the solar-B mission.

The normal-incidence efficiencies of two laminar gratings and the reflectances of two parabolic mirrors with matching multilayer coatings were measured by monochromatic synchrotron radiation and were compared with modeling calculations. These optics were developed for the Extreme-Ultraviolet Imaging Spectrometer to be launched on the Japanese Solar-B mission. Each optic has two sectors coated w...

متن کامل

A threshold photoelectron-photoion coincidence spectrometer with double velocity imaging using synchrotron radiation.

A novel threshold photoelectron-photoion coincidence (TPEPICO) imaging spectrometer at the U14-A beamline of the Hefei National Synchrotron Radiation Laboratory is presented. A set of open electron and ion lenses are utilized to map velocity imaging of photoelectrons and photoions simultaneously, in which a repelling electric field using an extra lens is applied to magnify images of photoelectr...

متن کامل

First experience with single-source, dual-energy CCTA for monochromatic stent imaging.

AIMS Single-source, dual-energy coronary computed tomography angiography (CCTA) with monochromatic image reconstruction allows significant noise reduction. The aim of the study was to evaluate the impact of monochromatic CCTA image reconstruction on coronary stent imaging, as the latter is known to be affected by artefacts from highly attenuating strut material resulting in artificial luminal n...

متن کامل

Swiss Light Source VUV beamline, Imaging photoelectron photoion coincidence spectroscopy

An imaging photoelectron photoion coincidence spectrometer at the vacuum ultraviolet (VUV) beamline of the Swiss Light Source is presented and a few initial measurements are reported. Monochromatic synchrotron VUV radiation ionizes the cooled or ambient temperature gas-phase sample. Photoelectrons are velocity focused, with a resolution better than 1 meV in order to detect threshold electrons. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied spectroscopy

دوره 60 1  شماره 

صفحات  -

تاریخ انتشار 2006