Utility of navigator-prospective acquisition correction technique (PACE) for reducing motion in brain MR imaging studies.

نویسندگان

  • J D Barnwell
  • J K Smith
  • M Castillo
چکیده

In this retrospective review, we demonstrate the utility of using a commercially available gated navigator sequence (prospective acquisition correction technique [PACE]) to reduce rhythmic breathing motion on brain MR images. For purposes of this report, we studied 2 sedated patients who had marked head rocking, one due to deep breathing and snoring and the other due to ventilator support. Motion degraded the routine images, which, despite a short acquisition time, were nondiagnostic. After application of PACE, a technique commonly used in abdominal studies, the brain images in both patients were judged to be of acceptable diagnostic quality. The use of PACE to diminish head motion is now routine at our institution when sedated or ventilated patients degrade images with involuntary head rocking.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Image-Based Retrospective and Optical Prospective Motion Correction for Diffusion Tensor Imaging

INTRODUCTION Correction of rigid head motion correction is important in diffusion tensor imaging because of the long acquisition times. Rigid head correction can be carried out either retrospectively prospectively. In this study, we compared the effectiveness of these two approaches in correcting motion artifacts in DTI. Retrospective correction was based on MR-based navigator data (1-3), whils...

متن کامل

Volumetric navigators for real-time motion correction in diffusion tensor imaging.

Prospective motion correction methods using an optical system, diffusion-weighted prospective acquisition correction, or a free induction decay navigator have recently been applied to correct for motion in diffusion tensor imaging. These methods have some limitations and drawbacks. This article describes a novel technique using a three-dimensional-echo planar imaging navigator, of which the con...

متن کامل

Prospective motion correction in brain imaging: a review.

Motion correction in magnetic resonance imaging by real-time adjustment of the imaging pulse sequence was first proposed more than 20 years ago. Recent advances have resulted from combining real-time correction with new navigator and external tracking mechanisms capable of quantifying rigid-body motion in all 6 degrees of freedom. The technique is now often referred to as "prospective motion co...

متن کامل

Autocorrection in MR imaging: adaptive motion correction without navigator echoes.

A technique for automatic retrospective correction of motion artifacts on magnetic resonance (MR) images was developed that uses only the raw (complex) data from the MR imager and requires no knowledge of patient motion during the acquisition. The algorithm was tested on coronal images of the rotator cuff in a series of 144 patients, and the improvements in image quality were similar to those a...

متن کامل

A patient-adapted navigator tracking approach for prospective 3D respiratory motion correction in free-breathing myocardial perfusion imaging

H. Pedersen, S. Ringgaard, W. Y. Kim The MR Research Centre, Skejby Hospital, Aarhus University Hospital, Aarhus N, Denmark INTRODUCTION Quantitative analysis of myocardial perfusion using free-breathing first-pass perfusion MRI is degraded by respiratory induced motion of the heart. Conventional strategies to correct this motion include the manual alignment of each image to fit a reference ima...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 28 4  شماره 

صفحات  -

تاریخ انتشار 2007