Reducing Measurement Bias in Long-time Dc- Measurements

نویسنده

  • Tamas B. BAKO
چکیده

This paper is an engineer-to-engineer note, to show a problematic point of long time DC measurements and show tips how to achieve higher accuracy there.. At long time measurements, rounding errors can seriously influence the output value. The problem is not just theoretical; our investigation is started because of a malfunctioning dilatation sensor system used at industrial turbines. We tried to determine the size of the error and reduce that with simple methods. In the followings, we will present the results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of time-ordered measurements of the two states in a niobium superconducting qubit structure

Measurements of thermal activation are made in a superconducting, niobium persistent-current qubit structure, which has two stable classical states of equal and opposite circulating current. The magnetization signal is read out by ramping the bias current of a dc superconducting quantum interference device. This ramping causes time-ordered measurements of the two states, where measurement of on...

متن کامل

The Dc Electrical Potential Method for the Measumment of Fretting Cracks

As fretting fatigue cracks are initiated at an early stage of life, the fretting fracture process is dominated by the stable growth of cracks. Hence the measurement of crack length is very important. This paper demonstrates the suitability of the DC potential drop technique for the measurement of fretting cracks. A calibration has been established for monitoring crack growth in BS L65 copper al...

متن کامل

Experimental Investigation of DC-RF Dispersion in AlGaN/GaN HFET’s Using Pulsed I-V and Time-Domain Waveform Measurements

AlGaN/GaN HFET’s have been analyzed under DC and RF Stimulus in an attempt to analyze the phenomenon of DC-RF dispersion. DC pulsed I-V measurements were performed where the pulse “off” state was set to different bias points, to simulate a class A bias condition at various drain voltages. RF timedomain waveform measurements were also performed. The I-V measurements exhibited the common problem ...

متن کامل

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

Nonlinear microwave impedance of short and long Josephson junctions

The nonlinear dependence on applied ac field (bv) or current (iv) of the microwave ~ac! impedance Rv 1iXv of both short and long Josephson junctions is calculated under a variety of excitation conditions. The dependence on the junction width is studied, for both field symmetric ~current antisymmetric! and field antisymmetric ~current symmetric! excitation configurations. The resistance shows st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010