Abdominal Aortic Intimal Flap Motion Characterization in Acute Aortic Dissection: Assessed with Retrospective ECG-Gated Thoracoabdominal Aorta Dual-Source CT Angiography
نویسندگان
چکیده
OBJECTIVES To evaluate the feasibility of dose-modulated retrospective ECG-gated thoracoabdominal aorta CT angiography (CTA) assessing abdominal aortic intimal flap motion and investigate the motion characteristics of intimal flap in acute aortic dissection (AAD). MATERIALS AND METHODS 49 patients who had thoracoabdominal aorta retrospective ECG-gated CTA scan were enrolled. 20 datasets were reconstructed in 5% steps between 0 and 95% of the R-R interval in each case. The aortic intimal flap motion was assessed by measuring the short axis diameters of the true lumen and false lumen 2 cm above of celiac trunk ostium in different R-R intervals. Intimal flap motion and configuration was assessed by two independent observers. RESULTS In these 49 patients, 37 had AAD, 7 had intramural hematoma, and 5 had negative result for acute aortic disorder. 620 datasets of 31 patients who showed double lumens in abdominal aorta were enrolled in evaluating intimal flap motion. The maximum and minimum true lumen diameter were 12.2 ± 4.1 mm (range 2.6 ∼ 17.4) and 6.7 ± 4.1 mm (range 0 ∼ 15.3) respectively. The range of intimal flap motion in all patients was 5.5 ± 2.6 mm (range 1.8 ∼ 10.2). The extent of maximum true lumen diameter decreased during a cardiac cycle was 49.5% ± 23.5% (range 12% ∼ 100%). The maximum motion phase of true lumen diameter was in systolic phase (5% ∼ 40% of R-R interval). Maximum and minimum intimal flap motion was at 15% and 75% of the R-R interval respectively. Intimal flap configuration had correlation with the phase of cardiac cycle. CONCLUSIONS Abdominal intimal flap position and configuration varied greatly during a cardiac cycle. Retrospective ECG-gated thoracoabdominal aorta CTA can reflect the actual status of the true lumen and provide more information about true lumen collapse. This information may be helpful to diagnosis and differential diagnosis of dynamic abstraction.
منابع مشابه
High-pitch dual-source CT angiography without ECG-gating for imaging the whole aorta: intraindividual comparison with standard pitch single-source technique without ECG gating.
PURPOSE We aimed to perform intraindividual comparison of computed tomography (CT) parameters, image quality, and radiation exposure between standard CT angiography (CTA) and high-pitch dual source (DS)-CTA, in subjects undergoing serial CTA of thoracoabdominal aorta. METHODS Eighteen subjects with thoracoabdominal CTA by standard technique and high-pitch DS-CTA technique within 6 months of e...
متن کاملAortic Dissection of Unknown Origin in a Young Patient: A Case Report
Aortic dissection occurs when a tear develops in the wall of the aorta, which is rare in the young population. This fatal disorder is hard to diagnose, especially in young patients. We present the case of aortic dissection in a 15-year-old boy referred to the Emergency Department of Yazd University of Medical Sciences in November 2015. The patient presented to our department with sudden acute c...
متن کاملComputed Tomography Imaging Artifact Simulating Type A Aortic Dissection.
Contrast-enhanced computed tomography (CT) is an effective tool for assessment of thoracic aortic disease in the modern era. Here, we describe a case of Type A aortic dissection incidentally detected by CT in a 63-year old man. Upon more precise imaging with electrocardiography (ECG)-gated CT, the dissection vanished, revealing it to be an aortic motion artifact. This report highlights the impo...
متن کاملProspective and retrospective ECG gating for thoracic CT angiography: a comparative study.
OBJECTIVE The objective of our study was to compare radiation dose, contrast load, thoracic aortic attenuation value, and image quality parameters of MDCT thoracic aortography performed with prospective and retrospective cardiac gating. MATERIALS AND METHODS Studies were performed on 80 patients (prospective ECG gating, n = 40; retrospective ECG gating, n = 40) either being evaluated for thor...
متن کاملTransabdominal Sonography in the Diagnosis of Acute Aortic Dissection Involving the Abdominal Aorta
Objective: Despite major advances in imaging techniques, correct diagnosis of acute aortic dissection is frequently missed. Although as many as one-third of acute cases of aortic dissection involve the abdominal aorta, emergency physicians rarely suspect this lethal disease in patients presenting with abdominal pain. Transabdominal sonography is typically employed by emergency physicians, but t...
متن کامل