The importance of commutability of reference materials used as calibrators: the example of ceruloplasmin.

نویسندگان

  • Ingrid Zegers
  • Robert Beetham
  • Thomas Keller
  • Joanna Sheldon
  • David Bullock
  • Finlay MacKenzie
  • Stefanie Trapmann
  • Hendrik Emons
  • Heinz Schimmel
چکیده

BACKGROUND Different methods for ceruloplasmin tend to give different results in external quality assessment schemes. During the production of the certified reference material ERM-DA470k/IFCC discrepant measurement results were also found for ceruloplasmin measured with different methods, and consequently the protein could not be certified in the material. METHODS We performed a commutability study with 30 serum samples and the reference materials ERM-DA470, ERM-DA470k/IFCC, and ERM-DA472/IFCC, using 6 different methods. Data were analyzed according to the CLSI Guideline C53-A to assess whether the reference materials had the same behavior as the serum samples with respect to measurement results obtained with combinations of the methods used. RESULTS Measurement results from different methods showed a good linear correlation for the serum samples. ERM-DA470 showed marked noncommutability for certain combinations of methods. ERM-DA470k/IFCC and ERM-DA472/IFCC were commutable for more combinations of methods. The lack of commutability of ERM-DA470 for certain combinations of methods correlates with results from the UK National External Quality Assessment Service showing discrepancies between results from these methods. For serum stored in the presence of sodium azide the results from different methods are essentially equivalent. CONCLUSIONS Ceruloplasmin in ERM-DA470 is a fully documented example of a situation in which, due to lack of commutability, the use of a common material for calibration did not lead to harmonization .

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Commutability still matters.

Commutability is a property of a reference material such that values measured for that reference material and for representative clinical samples have the same relationship between 2, or more, measurement procedures for the same measurand (1, 2 ). Commutability is required when a reference material will be used as a common calibrator for clinical laboratory measurement procedures or will be use...

متن کامل

Commutability of the ERM-DA470k reference material for two assays measuring serum albumin using immunochemical principles.

The standardization of measurements is a high-priority in Laboratory Medicine; its purpose being to achieve closer comparability of results for the same analyte obtained using different commercial systems (1). The promotion of result traceability to available higher-order reference measurement procedures and reference materials is the recommended approach (2). A major prerequisite for guarantee...

متن کامل

Harmonisation of factor VIII:C assay results: study within the framework of the Dutch project 'Calibration 2000'.

In a Dutch project for harmonisation of factor VIII coagulant activity (FVIII:C) assays, the commutability of potential calibrators for FVIII:C was assessed by means of a 'twin-study design', which is in essence a multi-centre, split-patient sample, between-field-methods protocol. Commutability was defined as the degree to which a material yielded the same numerical relationships between result...

متن کامل

Why commutability matters.

A fundamental goal of laboratory medicine is that results for patients’ samples will be comparable independent of the medical laboratory that produced the results. Routine measurement procedures of acceptable analytical specificity that have calibration traceable to the same higherorder reference material or reference measurement procedure should produce numerical values for clinical samples th...

متن کامل

Harmonization and external quality assessment of antithrombin activity assays.

UNLABELLED In the framework of a Dutch project named "Calibration 2000" harmonization of antithrombin activity assays was studied. The commutability of potential calibrators for antithrombin was assessed by means of a twin-study design, which is a multicentre, split-patient sample, between-field-methods protocol. The twin-study consisted of simultaneous analysis of fresh-frozen patient plasmas ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 59 9  شماره 

صفحات  -

تاریخ انتشار 2013