Rapid speciation analysis of Cr(VI) and Cr(III) by reversed-phase high-performance liquid chromatography with UV detection.

نویسندگان

  • Mohammad Abul Hossain
  • Mikio Kumita
  • Yoshimasa Michigami
  • Tajmeri S A Islam
  • Shigeru Mori
چکیده

A simple and rapid method is developed for the simultaneous determination of Cr(VI) and Cr(III) based on the formation of their different complexes with ammonium pyrrolidine-dithiocarbamate (APDC). Separation is performed using reversed-phase high-performance liquid chromatography coupled with UV detection. The conditions for complex formation and speciation are determined, such as solution pH, amount of APDC, temperature, and type of mobile phase. In order to substantially reduce the analysis time, the separation is carried out without extraction of chromium-APDC complexes from the mother liquor. Under the optimum analysis conditions, the chromatograms obtained show good peak separation, and the absolute detection limits (3s) are 2.2 microg/L for Cr(VI) and 4.5 microg/L for Cr(III). The calibration curves are linear from 3 to 5000 microg/L for Cr(VI) and 5 to 3000 microg/L for Cr(III). The relative standard deviations of peak areas in five measurements using a sample solution of 200 microg/L are less than 2% for Cr(VI) and 4% for Cr(III), indicating good reproducibility for this analytical method. Furthermore, simultaneous determination of Cr(VI) and Cr(III) is successful with the application of the proposed procedure in the synthetic wastewaters containing common heavy metal ions: Fe(III), Pb(II), Cd(II), Cu(II), and Zn(II).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Speciation of chromium metal ions by RP-HPLC.

A high-performance liquid chromatographic method with UV detection, based on chelation with morpholine-4-carbodithioate (MDTC), has been developed for the speciation of chromium. Simultaneous preconcentration of Cr(III) and Cr(VI) in aqueous solutions was achieved by extraction of metal species in chloroform as MDTC complexes. The separation of MDTC chelates of Cr(III) and Cr(VI) was realized o...

متن کامل

Speciation of Cr (III) and Cr (VI) Ions via Fabric Phase Sorptive Extraction for their Quantification via HPLC with UV Detection

Simultaneous extraction of the morpholino dithiocarbamate (MDTC) chelates of Cr(III) and Cr(VI) ion from aqueous samples was accomplished by applying fabric phase sorptive extraction (FPSE) using a cellulose fabric modified with a sol-gel/polytetrahydrofuran composite. Following extraction, the chelates were separated by HPLC on a reverse phase C18 column with acetonitrile:water (65:35; v/v) as...

متن کامل

Preconcentration method on modified silica fiber for chromium speciation.

A new method involving pre-concentration on modified silica fiber is described for the speciation of chromium(III) [Cr(III)] and chromium(VI) [Cr(VI)] in aqueous media. This method is based on the different chelating behavior of Cr(III) and Cr(VI) with morpholine-4-carbodithioate (MDTC). Both complexes are extracted on silica fiber modified by sol-gel technology by using 3-aminopropyltriethoxys...

متن کامل

A simple, sensitive and rapid isocratic reversed-phase high-performance liquid chromatography method for determination and stability study of curcumin in pharmaceutical samples

Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55...

متن کامل

Automation of liquid-liquid extraction-spectrophotometry using prolonged pseudo-liquid drops and handheld CCD for speciation of Cr(VI) and Cr(III) in water samples.

A simple spectrophotometric system, based on a prolonged pseudo-liquid drop device as an optical cell and a handheld charge coupled device (CCD) as a detector, was constructed for automatic liquid-liquid extraction and spectrophotometric speciation of trace Cr(VI) and Cr(III) in water samples. A tungsten halogen lamp was used as the light source, and a laboratory-constructed T-tube with two ope...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 43 2  شماره 

صفحات  -

تاریخ انتشار 2005