Reproducibility of native T1 mapping using ShMOLLI and MOLLI - implications for sample size calculation

نویسندگان

  • Anish N Bhuva
  • Sabrina Nordin
  • Heerajnarain Bulluck
  • Thomas A Treibel
  • Amna Abdel-Gadir
  • Stefania Rosmini
  • James C Moon
  • Charlotte Manisty
چکیده

Background Native T1 mapping is becoming established to help diagnose and monitor myocardial disease. The reproducibility of T1 mapping has not been well characterized, despite the important implications both for interpreting serial clinical studies, and for sample size calculation for surrogate endpoint in clinical trials. The SCMR consensus statement recommends measuring T1 in 2 imaging views. We investigated the test-retest reproducibility of two native T1 mapping techniques using different imaging views.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

T1 values in discrimination between health and disease using different T1 sequences: comparison between 3'3'5-MOLLI, 3'5-MOLLI, shMOLLI and SASHA

Background Myocardial T1 mapping is emerging as a promising means to non-invasively discriminate between normal and diseased myocardium. Original modified Look-Locker sequence (3’3’5-MOLLI) can induce a long breath-hold and is prone to cardiac and respiratory motion. Several shorter sequences (3’5MOLLI, shMOLLI and SASHA) have been proposed for acquisition of T1 values. We examined native and p...

متن کامل

Noncontrast myocardial T1 mapping using cardiovascular magnetic resonance for iron overload.

PURPOSE To explore the use and reproducibility of magnetic resonance-derived myocardial T1 mapping in patients with iron overload. MATERIALS AND METHODS The research received ethics committee approval and all patients provided written informed consent. This was a prospective study of 88 patients and 67 healthy volunteers. Thirty-five patients underwent repeat scanning for reproducibility. T1 ...

متن کامل

Reproducibility of native myocardial T1 mapping in the assessment of Fabry disease and its role in early detection of cardiac involvement by cardiovascular magnetic resonance

BACKGROUND Cardiovascular magnetic resonance (CMR) derived native myocardial T1 is decreased in patients with Fabry disease even before left ventricular hypertrophy (LVH) occurs and may be the first non-invasive measure of myocyte sphingolipid storage. The relationship of native T1 lowering prior to hypertrophy and other candidate early phenotype markers are unknown. Furthermore, the reproducib...

متن کامل

Are T1 values to characterize myocardial tissue equivalent between various sequences: comparison of MOLLI, shMOLLI, 3'5-MOLLI and SASHA

Background Classical modified Look-Locker sequence (MOLLI) can induce a long breath-hold and is prone to cardiac and respiratory motion. Several shorter sequences based on inversion (3’5MOLLI, shMOLLI) and saturation recovery (SASHA) of longitudinal relaxation have been proposed for derivation of T1 values or calculation of extracellular volume fraction or lambdas. Despite the validation in T1 ...

متن کامل

Comparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T

BACKGROUND T1 mapping based on cardiovascular magnetic resonance (CMR) is a novel approach using the magnetic relaxation T1 time as a quantitative marker for myocardial tissue composition. Various T1 mapping sequences are being used, with different strengths and weaknesses. Data comparing different sequences head to head however are sparse. METHODS We compared three T1 mapping sequences, ShMO...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2016