Solid-phase immunoassay of digoxin by measuring time-resolved fluorescence.
نویسندگان
چکیده
We describe a time-resolved fluoroimmunoassay for the cardiac glycoside digoxin. The assay depends on the competitive distribution of Eu3+-labeled anti-digoxin antibodies between solid-phase-bound digoxin and the digoxin in the sample or standard. After this immunoreaction, the bound fraction of the Eu3+-label is dissociated from the solid phase, converted into a highly fluorescent beta-diketone chelate, and measured in a fluorometer with time-resolution (1230 Arcus, LKB-Wallac). Sample volume is 20 microL, the incubation lasts 30 min, and the concentration range of the assay for digoxin is from 0.25 to 4.0 ng/mL (0.32-5.1 nmol of digoxin per liter). Correlation with an in-house RIA was good (r = 0.97, n = 43). The sensitivity was equivalent to that of most RIAs: 0.2 ng/mL (0.25 nmol/L).
منابع مشابه
Competitive solid-phase enzyme immunoassay for measuring digoxin in serum.
In this clinically useful enzyme immunoassay of digoxin in serum, we mix sample, beta-galactosidase-labeled digoxin, and anti-digoxin Fab fragments for 30 min at room temperature, then use Sepharose-bound second antibody for phase separation, and measure the unbound enzyme activity directly in the supernate of the equilibrium reaction mixture. The immunoassay buffer--phosphate-buffered isotonic...
متن کاملCross-reactivity of anti-digoxin antibodies with digitoxin depends on tracer structure.
The most common methods for measuring digoxin concentrations in serum are immunoassays. The prerequisite for exact determination of the digoxin value is an antibody that specifically binds digoxin. Because digitoxin differs from digoxin only in the C-12 hydroxy group, it is difficult to obtain anti-digoxin antibodies that do not cross-react with this compound. During the development of a fluore...
متن کاملDigoxin-like immunoreactivity eliminated from serum by centrifugal ultrafiltration before fluorescence polarization immunoassay of digoxin.
Digoxin determined in the Abbott "TDx" by fluorescence polarization immunoassay by the manufacturer's recommended method involving precipitation of protein with 5-sulfosalicylic acid (SSA) is subject to interference from endogenous compounds having digoxin-like immunoreactivity. Guided by the work of Graves et al. (Clin Chem 1986;32:1506-9), we eliminated interference caused by digoxin-like imm...
متن کاملEffect of protein concentration on the determination of digoxin in serum by fluorescence polarization immunoassay.
Determination of digoxin by fluorescence polarization immunoassay (FPIA) with the Abbott "TDx" is significantly influenced by the concentration of total serum protein. Each 10 g/L increase in serum protein results in an 8% decrease in measured digoxin. Studies with [3H]digoxin confirmed that digoxin binds to the protein pellet during the trichloroacetic acid precipitation step before the immuno...
متن کاملUltrasensitive thyrotropin immunoassay based on enzymatically amplified time-resolved fluorescence with a terbium chelate.
We describe an ultrasensitive, enzymatically amplified time-resolved fluorescence immunoassay of thyrotropin (thyroid-stimulating hormone) in serum with use of a terbium chelate as the detectable moiety. In this assay, thyrotropin is first simultaneously reacted with a solid-phase (microtiter well) monoclonal antibody and a soluble biotinylated monoclonal detection antibody. After washing, a st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 32 9 شماره
صفحات -
تاریخ انتشار 1986