Diagnostic Accuracy of Ultrasonography in Detection of Fetal Neural Tube Defects in Polyhydramnios

نویسندگان

  • Iffat Ara
  • Azmat Ali
  • Sanam Yasir
چکیده

Objective: The objective of the study was to determine the sensitivity and specificity of ultrasonography in the diagnosis of fetal neural tube defects in cases of polyhydramnios. Study Design: Descriptive type of study. Place and duration of study: It was conducted in Radiology department of Mother and Child Hospital (MCH) in collaboration with gynaecology department of Mother and Child hospital (MCH), Pakistan Institute of Medical Sciences, Islamabad. Patients selected for study was both indoor and outpatient department cases referred for ultrasonography. Duration of study was one year. Materials & Methods: In this study sixty (60) cases with the clinical suspicion of polyhydramnios were included. 3.5 Mega Hertz convex transducer was used for sonological assessment of these patients. Ultrasound findings were compared with the fetal outcome after delivery. Data was analyzed on SPSS 10.0 version and 2 x 2 tables were used to calculate test performance characteristic of Ultrasound finding. Results: Total number of patients in our study was 60. Out of these 40 patients (66.6%) were ultrasound positive for neural tube defects which were confirmed by comparison with fetal outcome after delivery and considered true positive, while no patient was false positive. Out of these 18 (30.0%) were true negative while 2 (3.4%) were false negative, as confirmed subsequently by comparison with outcome after delivery. The sensitivity, specificity, positive, negative predictive values and diagnostic accuracy of ultrsonography for neural tube defect in polyhydramnios was 95.2%, 100%, 100%, 90% and 96.6% respectively. Conclusion: The sensitivity, specificity, positive predictive values and overall diagnostic efficacy of ultrasonography make it a modality of choice for detection of fetal neural tube defects in cases of polyhydramnios. It should be used as a primary screening investigation in patients with high clinical suspicion, since it is a safe, cost-effective, easy to perform and radiation free imaging technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of arsenic on neural tube in mouse embryo and relation to reduced folate carrier (RFC-1)

Arsenic is an important environmental toxicant which is usually found in drinking water in inorganic form. The hypothesis tested in this investigation is; arsenic exposure causes neural tube defects (NTDs) andthese defects of the central nervous system are more likely related to folate deficiency during fetal life. In this study, sodium arsenate was administered via intraperitoneal route at a r...

متن کامل

Value of sagittal color Doppler ultrasonography as a supplementary tool in the differential diagnosis of fetal cleft lip and palate

PURPOSE The purpose of this study was to evaluate the feasibility and usefulness of sagittal color Doppler ultrasonography (CDUS) for the diagnosis of fetal cleft lip (CL) and cleft palate (CP). METHODS We performed targeted ultrasonography on 25 fetuses with CL and CP, taking coronal and axial images of the upper lip and maxillary alveolar arch in each case. The existence of defects in and m...

متن کامل

Prenatal diagnosis of neural tube defects.

A prospective program for the prenatal detection of neural tube defects in a high-risk pregnancy group has been under way for one year. Twenty high-risk mothers have undergone a complete prenatal work-up, including sonography, amniocentesis, and amniotic fluid and maternal serum alpha-fetoprotein quantitation. Within this group, two cases were prospectively diagnosed and were later confirmed.

متن کامل

The Accuracy of Ultrasonography in Compared with Computed Tomography in Detection of Anterior Mediastinal Neoplasms

Abstract Background The aim of this study was to evaluate sensitivity and specificity of mediastinal sonography, and compared with CT, in detection of anterior mediastinal neoplasms. Materials and Methods The sonography with convex probes (5.0 and 7.5 MHz) was done prospectively for 34 patients (from 2 to 25 years old) with mediastinal mass. The results were compared with the results of ...

متن کامل

اثرات تراتوژنیک فنی‌‌توئین برتکوین لوله عصبی و اسکلتی‌جنین‌های موش سوری

Abstract Background: Phenytoin is one of the oldest anti epileptic drugs it may result in fetal abnormalities if taken during pregnancy. This study was designed to determine teratogenic effects of phenytoin on the development of skeleton and neural tube defects in mouse fetuses.. Materials and methods: Forty small experimental pregnant mice (NMRI Type) were divided in to three experimental...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013