TU-E-217BCD-08: Extraction and Insertion of Tumor Masses in Cone Beam Breast CT Images.

نویسندگان

  • C Lai
  • Y Shen
  • Y Zhong
  • G Whitman
  • W Yang
  • T Wang
  • C Shaw
چکیده

PURPOSE To develop and validate algorithms for extraction and insertion of three-dimensional (3D) profiles of tumor masses in cone beam breast CT (CBBCT) images to create simulated abnormality for evaluation with observer performance study. METHODS A bench-top experimental CBBCT scanner was constructed and used to image mastectomy breast specimens with IRB approval. 5 sets of CBBCT images with confirmed tumor masses and 2 sets of normal CBBCT images were selected and used for this study. All CBBCT images were first corrected for cupping artifacts. The corrected images were then processed to reduce their noise levels and form the denoised images. The corrected and denoised CBBCT images for normal breasts were then segmented into adipose and glandular voxels. The images for abnormal breasts were reviewed by mammographers with the help of clinical images and reports to delineate the tumor masses and form 3D tumor maps. Using these maps, the 3D tumor profiles were rescaled to average glandular signals around the insertion locations in normal images. The boundaries of the 3D rescaled tumor profiles were smoothed to avoid sharp edge. The resultant 3D tumor profiles were inserted onto cupping artifact corrected normal CBBCT images by replacing the signals in adipose voxels near the insertion locations. The cupping artifacts were then added back to generate the simulated abnormal CBBCT images. These images were then visually compared with actual abnormal images for their degree of realism. RESULTS Based on visual comparison, the simulated abnormal CBBCT images showed no significant difference in realism from actual abnormal CBBCT images. CONCLUSIONS We have successfully demonstrated the technique to extract 3D tumor profiles from abnormal CBBCT images and insert them onto normal CBBCT images to form simulated abnormal images for use in observer performance study. This work was supported in part by grants CA104759, CA13852 and CA124585 from the NIH-NCI, a research grant EB00117 from the NIH-NIBIB, and a subcontract from NIST-ATP.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی دقت رادیوگرافی پانورامیک در تعیین ارتباط ریشه دندان‌های خلفی فک بالا با سینوس ماگزیلای به کمک Cone-Beam CT

  Background and Aims: It is crucial to verify the relationship between root apices and maxillary sinus floor in some surgical procedures like extraction and implant placement or in orthodontic movements like intrusion. Protrusion of roots into the sinus increases the risk of post extraction pneumatization which in turn decreases the available bone at the implant or denture sites. The aim of th...

متن کامل

TU-E-217BCD-04: Spectral Breast CT: Effect of Adaptive Filtration on CT Numbers, CT Noise, and CNR.

PURPOSE Photon counting spectral breast CT is feasible in part due to using an adaptive filter. An adaptive filter provides flat x-ray intensity profile and constant x-ray energy spectrum across detector surface, decreases required detector count rate, and eliminates beam hardening artifacts. However, the altered x-ray exposure profiles at the breast and detector surface may influence the distr...

متن کامل

Breast metastasis from the pancreatic neuroendocrine tumor origin detected by 99mTc-Octreotate scan

A 50 years old woman with history of pancreatic neuroendocrine tumor diagnosed 2 years ago, which has not been surgically removed,was referred to our department for a 99mTc-Octreotate in order to evaluate the somatostatin receptor status. She was treated with regular sandostatin injections and chemotherapy. Her CT scan which was previously performed confirmed lung, adrenal and hepati...

متن کامل

A feasibility study on the use of MV-CBCT images for urgent palliative treatment planning

Introduction: The application of 3D volumetric imaging modalities in treatment planning of radiation therapy can provide more precisely define tumor localization, and computed tomography (CT) is the most common accepted method for treatment planning. Given the lack of a CT scanner stationed in all radiotherapy departments and equipping most of the medical linear accelerators wi...

متن کامل

Simulation of Mammograms & Tomosynthesis imaging with Cone Beam Breast CT images

The use of mammography techniques for the screening and diagnosis of breast cancers has been limited by the overlapping of cancer symptoms with normal tissue structures. To overcome this problem, two methods have been developed and actively investigated recently: digital tomosynthesis mammography and cone beam breast CT. Comparison study with these three techniques will be helpful to understand...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part24  شماره 

صفحات  -

تاریخ انتشار 2012