Noninvasive measurement of intra-aneurysmal pressure and flow pattern using phase contrast with vastly undersampled isotropic projection imaging.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Currently, more reliable parameters to predict the risk of aneurysmal rupture are needed. Intra-aneurysmal pressure gradients and flow maps could provide additional information regarding the risk of rupture. Our hypothesis was that phase contrast with vastly undersampled isotropic projection reconstruction (PC-VIPR), a novel 3D MR imaging sequence, could accurately assess intra-aneurysmal pressure gradients in a canine aneurysmal model when compared with invasive measurements. MATERIALS AND METHODS A total of 13 surgically created aneurysms in 8 canines were included in this study. Pressure measurements were performed in the parent vessel, aneurysm neck, and 5 regions within the aneurysmal sac with a microcatheter. PC-VIPR sequence was used to obtain cardiac-gated velocity measurements in a region covering the entire aneurysm. The velocity and pressure gradient maps derived from the PC-VIPR data were then coregistered with the anatomic DSA images and compared with catheter measurements. RESULTS In 7 of the bifurcation aneurysms, the velocity flow maps demonstrated a recirculation flow pattern with a small neck-to-dome pressure gradient (mean, +0.5 mm Hg). In 1 bifurcation aneurysm, a flow jet extending from the neck to the dome with significantly greater pressure gradient (+50.2 mm Hg) was observed. All sidewall aneurysms had low flow in the sac with intermediate pressure gradients (mean, +8.3 mm Hg). High statistical correlation existed between PC-VIPR aneurysmal pressures and microcatheter pressure measurements (R = 0.82, P < .01). CONCLUSION PC-VIPR can provide anatomic as well as noninvasive quantitative and qualitative hemodynamic information in the canine aneurysm model. The PC-VIPR intra-aneurysmal pressure measurements correlated well with catheter measurements.
منابع مشابه
Physiologic and anatomic assessment of a canine carotid artery stenosis model utilizing phase contrast with vastly undersampled isotropic projection imaging.
BACKGROUND AND PURPOSE Noninvasive assessment of the hemodynamic significance of carotid stenosis is often performed with MR angiography and supplemented with carotid Doppler sonography. Phase contrast with vastly undersampled isotropic projection reconstruction (PC-VIPR), a novel MR imaging technique, accelerates phase-contrast MR flow imaging and provides both images of the vessels and measur...
متن کاملECE 533: Report Vessel Branch Segmentation of Phase Contrast Vastly undersampled Isotropic PRojection Magnetic Resonance Imaging
متن کامل
Time-resolved angiography: Past, present, and future.
The introduction of digital subtraction angiography (DSA) in 1980 provided a method for real time 2D subtraction imaging. Later, 4D magnetic resonance (MR) angiography emerged beginning with techniques like Keyhole and time-resolved imaging of contrast kinetics (TRICKS) that provided frame rates of one every 5 seconds with limited spatial resolution. Undersampled radial acquisition was subseque...
متن کاملPC VIPR for Comprehensive Cardiovascular Evaluation in Congenital Heart Disease
Introduction Imaging of congenital heart disease usually requires multiple anatomical and functional scans followed by several 2D phase contrast (PC) acquisitions in a variety of oblique scan planes for flow measurements. A new PC acquisition technique has been developed using vastly undersampled isotropic projection reconstruction (PC VIPR) [1], which allows for volumetric 3D CINE flow imaging...
متن کاملPC VIPR: a high-speed 3D phase-contrast method for flow quantification and high-resolution angiography.
BACKGROUND AND PURPOSE Three-dimensional phase-contrast (3DPC) is limited by long imaging times, limited coverage, flow artifacts, and the need to perform multiple additional 2D examinations (2DPC) to measure flow. A highly undersampled 3D radial acquisition (isotropic-voxel radial projection imaging [PCVIPR]) makes it possible to increase the product of volume coverage and spatial resolution b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 28 9 شماره
صفحات -
تاریخ انتشار 2007