A Biomechanical Analysis of an Artificial Disc With a Shock-absorbing Core Property by Using Whole-cervical Spine Finite Element Analysis.
نویسندگان
چکیده
STUDY DESIGN A biomechanical comparison among the intact C2 to C7 segments, the C5 to C6 segments implanted with fusion cage, and three different artificial disc replacements (ADRs) by finite element (FE) model creation reflecting the entire cervical spine below C2. OBJECTIVE The aim of this study was to analyze the biomechanical changes in subaxial cervical spine after ADR and to verify the efficacy of a new mobile core artificial disc Baguera C that is designed to absorb shock. SUMMARY OF BACKGROUND DATA Scarce references could be found and compared regarding the cervical ADR devices' biomechanical differences that are consequently related to their different clinical results. METHODS One fusion device (CJ cage system, WINNOVA) and three different cervical artificial discs (Prodisc-C Nova (DePuy Synthes), Discocerv (Scient'x/Alphatec), Baguera C (Spineart)) were inserted at C5-6 disc space inside the FE model and analyzed. Hybrid loading conditions, under bending moments of 1 Nm along flexion, extension, lateral bending, and axial rotation with a compressive force of 50 N along the follower loading direction, were used in this study. Biomechanical behaviors such as segmental mobility, facet joint forces, and possible wear debris phenomenon inside the core were investigated. RESULTS The segmental motions as well as facet joint forces were exaggerated after ADR regardless of type of the devices. The Baguera C mimicked the intact cervical spine regarding the location of the center of rotation only during the flexion moment. It also showed a relatively wider distribution of the contact area and significantly lower contact pressure distribution on the core than the other two devices. A "lift off" phenomenon was noted for other two devices according to the specific loading condition. CONCLUSION The mobile core artificial disc Baguera C can be considered biomechanically superior to other devices by demonstrating no "lift off" phenomenon, and significantly lower contact pressure distribution on core. LEVEL OF EVIDENCE N/A.
منابع مشابه
Effect of Artificial Disc Position on Spine Biomechanics in the Cervical Spine: A Finite Element Study
INTRODUCTION Total disc replacement(TDR) has been suggested for surgical method to treat degenerative disc disease of the cervical spine because it decompresses nerves and preserves motion segments. The short-term outcomes of the TDR of cervical spine has been well reported to treat degenerative disc diseases as a motion preservation technique in spite of some clinical controversies such as imp...
متن کاملBiomechanical analysis of the cervical spine following total disc arthroplasty : an experimental and finite element investigation
Approved: ____________________________________ Thesis Supervisor ____________________________________ Title and Department ____________________________________ Date 3 BIOMECHANICAL ANALYSIS OF THE CERVICAL SPINE FOLLOWING TOTAL DISC ARTHROPLASTY: AN EXPERIMENTAL AND FINITE ELEMENT INVESTIGATION
متن کاملAssociation between extent of simulated degeneration of C5-C6 disc and biomechanical parameters of a model of the full cervical spine: a finite element analysis study.
PURPOSE To delineate the association between extent of degeneration of the disc at C5-C6, simulated in a model of the full cervical spine, and biomechanical responses of the model. METHODS A validated three-dimensional model of an intact, healthy, adult full cervical spine (C1-C7) was constructed. This model was then modified to create three models simulating mild, moderate, and severe grades...
متن کاملEstimation of spinal loads using a detailed finite element model of the L4-L5 lumbar segment derived by medical imaging kinematics; a feasibility study
Introduction: Low back pain is the most prevalent orthopedic disorder and the first main cause of poor working functionality in developed as wells as many developing countries. In Absence of noninvasive in vivo measurement approaches, biomechanical models are used to estimate mechanical loads on human joints during physical activities. To estimate joint loads via musculoskelet...
متن کاملEvaluation of the role of ligaments, facets and disc nucleus in lower cervical spine under compression and sagittal moments using finite element method.
Cervical spinal instability due to ligamentous injury, degenerated disc and facetectomy is a subject of great controversy. There is no analytical investigation reported on the biomechanical response of cervical spine in these respects. Parametric study on the roles of ligaments, facets, and disc nucleus of human lower cervical spine (C4-C6) was conducted for the very first time using noninvasiv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Spine
دوره 41 15 شماره
صفحات -
تاریخ انتشار 2016