Platelet function during cardiopulmonary bypass using multiple electrode aggregometry: comparison of centrifugal and roller pumps.
نویسندگان
چکیده
Blood trauma may be lower with centrifugal pumps (CPs) than with roller pumps (RPs) during cardiopulmonary bypass (CPB), because, unlike RPs, CPs do not compress the tubing, and shear stress is considered lower in CPs than in RPs. However, relative platelet function remains unclear. Using multiple electrode aggregometry (MEA), we compared platelet function with CP and RP. Ten swine underwent CPB for 3 h, with five weaned off using CP and five using RP. Platelet function was measured using MEA, as were hemoglobin concentration and platelet count, before sternotomy, after heparin infusion, 30 min and 3 h after starting CPB, after protamine infusion, and 60 min after stopping CPB. Platelet activation was initiated with adenosine diphosphate (ADP), arachidonic acid (AA), and thrombin receptor-activating protein 6 (TRAP). Fibrinogen, platelet factor 4 (PF4), and β-thromboglobin (β-TG) concentrations were measured before sternotomy and 60 min after stopping CPB. In the CP group and using ADP, aggregation was significantly reduced 30 min (P = 0.019) and 3 h (P = 0.027) after starting CPB, recovering to baseline 60 min after CPB was stopped. In the RP group, aggregation was significantly decreased 30 min (P = 0.007) and 3 h (P = 0.003) after starting CPB and after protamine administration (P = 0.028). With AA, aggregation significantly decreased 30 min after starting CPB in both the CP (P = 0.012) and RP (P = 0.016) groups, slightly increasing 3 h after starting CPB and after protamine infusion, and recovering to baseline 60 min after CPB cessation. With TRAP, aggregation in the CP and RP groups decreased 30 min after starting the pump, although changes were not significant; aggregation gradually recovered after 3 h and returned to baseline 60 min after the pumps were stopped. There were no significant differences at all sampling points of MEA. In both groups, fibrinogen, PF4, and β-TG concentrations were similar 60 min after pump cessation and before sternotomy. Platelet function, evaluated with MEA, was lowest 30 min after CPB was started but did not decrease over time in either group. As assessed by MEA, platelet function using CP and RP did not differ significantly. Platelet dysfunction was caused mainly by initial contact with foreign materials and may not be dependent on type of pump.
منابع مشابه
Variations in battery life of a heart-lung machine using different pump speeds, pressure loads, boot material, centrifugal pump head, multiple pump usage, and battery age.
Electrical failure during cardiopulmonary bypass (CPB) has previously been reported to occur in 1 of every 1500 cases. Most heart-lung machine pump consoles are equipped with built-in battery back-up units. Battery run times of these devices are variable and have not been reported. Different conditions of use can extend battery life in the event of electrical failure. This study was designed to...
متن کاملElectrostatic potential generated during extracorporeal pump prime circulation before cardiopulmonary bypass initiation.
The development of electrostatic potentials generated during cardiopulmonary bypass (CPB) procedures using polyvinylchloride (PVC) tubing in conjunction with roller pumps has been previously documented. The resulting damage from the electrostatic discharge (ESD) has been reported to affect gas transfer devices, but details of potential damage to electronic components commonly used during extrac...
متن کاملSignificant safety advantages gained with an improved pressure-regulated blood pump.
A prototype of a non-occlusive pressure-regulated blood pump (M-pump) was evaluated in-vitro for safety in a comparative study with the roller and centrifugal pumps. The M-pump consists of collapsible tubing of unique design wrapped under tension around a rotor without a stator. The prototype M-pumps were tested in vitro to evaluate performance with respect to flow/ pressure characteristics, he...
متن کاملBlood flow and damage by the roller pumps during cardiopulmonary bypass
Although much CFD work has been carried out to study the blood damage created in a centrifugal pump used for a cardiopulmonary bypass, little is known about the blood flow and consequent damage in a roller pump. A timedependent moving boundary problem is solved in this paper to explore the blood flow and damage in the roller pump. An initial attempt to predict the blood damage from these simula...
متن کاملEffect of different pump heads for CPB on early cognitive outcome after coronary artery bypass surgery.
OBJECTIVES Reduction of cognitive function is a possible side effect after coronary artery surgery using cardiopulmonary bypass (CPB). We investigated the effect of roller versus centrifugal pumps for CPB on cognitive performance in patients undergoing coronary artery bypass grafting (CABG). METHODS 50 consecutive CABG patients operated with centrifugal pump were compared to 50 roller pump pa...