Investigating Protein Folding and Unfolding in Electrospray Nanodrops Upon Rapid Mixing Using Theta-Glass Emitters

نویسندگان

  • Daniel N. Mortensen
  • Evan R. Williams
چکیده

Theta-glass emitters are used to rapidly mix two solutions to induce either protein folding or unfolding during nanoelectrospray (nanoESI). Mixing acid-denatured myoglobin with an aqueous ammonium acetate solution to increase solution pH results in protein folding during nanoESI. A reaction time and upper limit to the droplet lifetime of 9 ± 2 μs is obtained from the relative abundance of the folded conformer in these rapid mixing experiments compared to that obtained from solutions at equilibrium and a folding time constant of 7 μs. Heme reincorporation does not occur, consistent with the short droplet lifetime and the much longer time constant for this process. Similar mixing experiments with acid-denatured cytochrome c and the resulting folding during nanoESI indicate a reaction time of between 7 and 25 μs depending on the solution composition. The extent of unfolding of holo-myoglobin upon rapid mixing with theta-glass emitters is less than that reported previously ( Fisher et al. Anal. Chem. 2014 , 86 , 4581 - 4588 ), a result that is attributed to the much smaller, ∼1.5 μm, average o.d. tips used here. These results indicate that the time frame during which protein folding or unfolding can occur during nanoESI depends both on the initial droplet size, which can be varied by changing the emitter tip diameter, and on the solution composition. This study demonstrates that protein folding or unfolding processes that occur on the ∼10 μs time scale can be readily investigated using rapid mixing with theta-glass emitters combined with mass spectrometry.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microsecond and nanosecond polyproline II helix formation in aqueous nanodrops measured by mass spectrometry.

The 1.5 μs and <400 ns time constants for the formation of polyproline II helix structures in 21 and 16 residue peptides, respectively, are measured using rapid mixing from theta-glass emitters coupled with mass spectrometry. Results from these studies should serve as useful benchmarks for comparison with computational simulation results.

متن کامل

Theta-Glass Capillaries in Electrospray Ionization: Rapid Mixing and Short Droplet Lifetimes

Double-barrel wire-in-a-capillary electrospray emitters prepared from theta-glass capillaries were used to mix solutions during the electrospray process. The relative flow rate of each barrel was continuously monitored with internal standards. The complexation reaction of 18-crown-6 and K(+), introduced from opposite barrels, reaches equilibrium during the electrospray process, suggesting that ...

متن کامل

Solvent gradient electrospray for laser ablation electrospray ionization mass spectrometry.

Most electrospray based ambient ionization techniques, e.g., laser ablation electrospray ionization (LAESI), utilize a fixed spray solution composition. Complex samples often contain compounds of different polarity that exhibit a wide range of solubilities in the electrospray solvent. Thus, the fixed spray solution composition limits the molecular coverage of these approaches. Two-barrel theta ...

متن کامل

Novel methods for manipulating ion types in the solution and gas phases for the structural analysis of biomolecules using Mass Spectrometry

Fisher, Christine M. Ph.D., Purdue University, May 2015. Novel Methods for Manipulating Ion Types in the Solution and Gas Phases for the Structural Analysis of Biomolecules Using Mass Spectrometry. Major Professor: Scott McLuckey. Mass Spectrometry has become a valuable tool for the analysis of a variety of molecules, making it applicable to many fields. The advent...

متن کامل

Folded emitters for nanoelectrospray ionization mass spectrometry.

Electrospray ionization (ESI) has revolutionized mass spectrometry (MS), providing a facile method for the ionization of macromolecules for analysis by mass. The development of nanoESI-MS has further extended the utility of ESI-MS, permitting the analysis of small-volume samples with enhanced sensitivity over conventional ESI-MS. Traditional nanoESI-MS experiments use pulled-glass capillary emi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 87  شماره 

صفحات  -

تاریخ انتشار 2015