Power Line Cable Transfer Function for Modelling of Power Line Communication System

نویسندگان

  • Petr Mlýnek
  • Martin Koutný
چکیده

This paper presents the design of a power line communication model. Primarily, it is focused on a realization of a communication model with a power line channel. The model is composed of a PLC communication model, a model of power lines and a noise model. Power lines are modelled through a chain parameter describing the relation between the input and output voltage and current of the two-port network.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis and Experimental Evaluation of Power Line Transmission Parameters for Power Line Communication

The article describes a way of evaluating the power line channel frequency response and input impedance by means of the linear time-invariant (LTI) power line generator. Two possible methods are introduced for the calculation of primary parameters: the first method depends on the physical realization and physical dimension of the cable, and the second method is derived from the data provided by...

متن کامل

Investigation of Indoor Low-voltage Cables as Data Communication Channels

Power Line Communication (PLC) has been considered as attractive media for high speed data transmission, particularly for applications like home networking, internet, voice and data services. For the use of the low voltage networks as high speed data channel the path carrier frequencies within the range up to 30 MHz must be considered. The development of suitable communication systems and the p...

متن کامل

Evaluating the potential of cascading failure occurrence due to line outage in power systems by information theory method and radial base functions

In power systems, a connected topology is created to increase reliability and economic performance. Increasing dimensions of power systems on the one hand and the need to continuously monitor power systems for secure operation on the other challenge the evaluation of power system security. In such conditions, due to economic conditions and considering the fast growth of consumers in a power sys...

متن کامل

A Reliable and Economically Feasible Automatic Meter Reading System Using Power Line Distribution Network (TECHNICAL NOTE)

Automatic Meter Reading (AMR) is the remote collection of consumption data from customer’s utility meters over telecommunications, radio, power line and other links. AMR provides water, electric and gas utility−service companies the opportunities to streamline metering, billing and collection activities, increase operational efficiency and improve customer service. Utility company uses technolo...

متن کامل

A Suitable Coding Scheme for Broadband Power-line Communication

This paper introduces three coding strategies for using the Luby Transform (LT) code in a relay aided power-line communication scheme. In the first method, the relay decodes the received packets and re-encodes them for transmission towards the destination. In the second method, the relay only forwardes a random linear combination of its received packets towards the destination, while in the thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011