The duration of balloon inflation affects the luminal diameter of coronary segments after bioresorbable vascular scaffolds deployment
نویسندگان
چکیده
BACKGROUND Adequate expansion is critical to achieve optimal Bioresorbable Vascular Scaffolds (BVS) apposition to the vessel wall. However, compared to metallic stents, BVS present different mechanical properties. Hence, slow deployment and maintenance of balloon inflation for at least 30" is recommended for BVS implantation. However, since no evidences are available demonstrating the superiority of a longer balloon dilatation time, the implantation technique is highly variable among different centers. METHODS A total of 24 BVS-treated lesions were included in the present analysis. After BVS deployment at 12 atmosphere (ATM) the balloon was rapidly deflated and scaffold expansion was documented with an angiogram. The same balloon was then inflated again and kept at 12 ATM for 30". Finally, a further angiogram was obtained to evaluate BVS expansion. Quantitative coronary angiography (QCA) was performed at each step. RESULTS A significant increase of minimal luminal diameter (MLD)-to-reference scaffold diameter (RSD) ratio (MLD to RSD Ration, MR-Ratio) from 0.70 ± 0.10 after initial stent deployment to 0.79 ± 0.10 after the 30"-long balloon dilation was observed (p < 0.001). Of note, this result was consistent across all sub-segments, as well as across almost all lesion subgroups. A substantial reduction in the prevalence of residual stenosis from 29 % to 17 % was registered after the 30"-long dilation. CONCLUSIONS Our results strongly support the maintenance of balloon inflation for at least 30" during BVS deployment to achieve optimal scaffold expansion and minimize the occurrence of residual stenosis.
منابع مشابه
Cutting balloon use may ease the optimal apposition of bioresorbable vascular scaffold in in-stent stenosis
Bioresorbable vascular scaffolds (BVS) have different mechanical properties as compared to metallic stents. Therefore, the standard procedural technique to achieve appropriate deployment may differ. Utilisation of debulking techniques, including cutting balloon and directional atherectomy prior to BVS deployment, is still questionable. Herein, we discuss a case of coronary in-stent restenosis a...
متن کاملCoronary magnetic resonance imaging after routine implantation of bioresorbable vascular scaffolds allows non-invasive evaluation of vascular patency
BACKGROUND Evaluation of recurrent angina after percutaneous coronary interventions is challenging. Since bioresorbable vascular scaffolds (BVS) cause no artefacts in magnetic resonance imaging (MRI) due to their polylactate-based backbone, evaluation of vascular patency by MRI might allow for non-invasive assessment and triage of patients with suspected BVS failure. METHODS Patients with pol...
متن کاملOne-Year Clinical and Computed Tomography Angiographic Outcomes After Bioresorbable Vascular Scaffold Implantation During Primary Percutaneous Coronary Intervention for ST-Segment-Elevation Myocardial Infarction: The PRAGUE-19 Study.
BACKGROUND Bioresorbable vascular scaffolds (BVS) represent promising new technology, but data on their long-term outcomes in ST-segment-elevation myocardial infarction (STEMI) setting are missing. The aim was to analyze 1-year clinical and computed tomographic angiographic outcomes after BVS implantation in STEMI. METHODS AND RESULTS PRAGUE-19 is a prospective multicenter single-arm study en...
متن کاملThe absorb bioresorbable vascular scaffold in coronary bifurcations: insights from bench testing.
OBJECTIVES This study sought to evaluate the feasibility of performing contemporary bifurcation techniques with the Absorb everolimus-eluting bioresorbable vascular scaffold (Abbott Vascular, Santa Clara, California) (BVS). BACKGROUND The feasibility of using the BVS in bifurcation lesions is unknown. METHODS We performed bifurcation stenting procedures including main-vessel stenting with b...
متن کاملAcute clinical and angiographic results with the new AVE Micro coronary stent in bailout management.
To determine the feasibility and safety of development of this new stent, we deployed 28 AVE Micro stents in 23 native coronary artery lesions in 20 patients who developed acute or threatened closure after balloon angioplasty (BA). Ten stents were deployed in the left anterior descending artery, 10 in the circumflex, and 8 in the right coronary artery. Luminal dimensions were measured using a c...
متن کامل