CT fluoroscopy-guided cervical interlaminar steroid injections: safety, technique, and radiation dose parameters.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Cervical epidural steroid injections are approached with trepidation because of concerns over safety, including direct spinal cord injury. CT fluoroscopy is an alternative to conventional fluoroscopy that could potentially help reduce the risk of injury by providing improved localization of the needle tip. We sought to determine rates of technical success and risk of complications in our initial cohort of patients treated with cervical interlaminar ESI performed under CTF guidance. MATERIALS AND METHODS In this retrospective case series, we reviewed procedural details and CTF images of 53 consecutive cervical interlaminar ESIs performed on 50 patients over a period of 8 months. Rates of technical success, incidence of complications, procedure times, and factors that influence radiation exposure were examined. RESULTS No symptomatic procedural complications were observed. A single case of intrathecal contrast injection was observed, from which the patient was asymptomatic. The remaining injections were all technically successful. Injections were performed at every cervical level, as high as C1-C2. Total procedure times averaged less than 20 minutes. Average CT fluoroscopic time was 24 seconds and median tube current was 70 mA. CONCLUSIONS CTF-guided cervical interlaminar ESI can be performed at all levels in the cervical spine with a low rate of procedural complications. Short total procedure times, CT-fluoroscopy times, and reduced tube current make this procedure a practical alternative to cervical ESI performed under conventional fluoroscopy.
منابع مشابه
CT fluoroscopy-guided cervical interlaminar steroid injections: is it overkill?
Injections: Is It Overkill? We read with great interest the article by Kranz et al in the August 2012 issue of AJNR entitled, “CT Fluoroscopy-Guided Cervical Interlaminar Steroid Injections: Safety, Technique, and Radiation Dose Parameters.” The authors concluded that CT fluoroscopy (CTF)– guided epidural steroid injections (ESIs) can be performed with a low rate of procedural complications and...
متن کاملRadiation dose for 345 CT-guided interlaminar lumbar epidural steroid injections.
BACKGROUND AND PURPOSE CT guidance is increasingly being used to localize the epidural space during epidural steroid injections. A common concern is that CT may be associated with significantly higher radiation doses compared with conventional fluoroscopy. The goal of this retrospective study was to determine the average dose-length product and effective dose delivered while interlaminar epidur...
متن کاملPATIENT SAFETY Radiation Dose for 345 CT-Guided Interlaminar Lumbar Epidural Steroid Injections
BACKGROUNDAND PURPOSE: CT guidance is increasingly being used to localize the epidural space during epidural steroid injections. A common concern is that CTmay be associatedwith significantly higher radiation doses comparedwith conventional fluoroscopy. The goal of this retrospective study was to determine the average dose-length product and effective dose delivered while interlaminar epidural ...
متن کاملInadvertent Intrafacet Injection during Lumbar Interlaminar Epidural Steroid Injection: A Comparison of CT Fluoroscopic and Conventional Fluoroscopic Guidance.
BACKGROUND AND PURPOSE Inadvertent intrafacet injection can occur during interlaminar epidural steroid injection, resulting in a false-positive loss of resistance and nontarget injection of medication. The purpose of this investigation was to compare the observed rates of this phenomenon during lumbar interlaminar epidural steroid injection performed by using conventional fluoroscopic and CT fl...
متن کاملRadiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations
BACKGROUND The sacroiliac (SI) joint is frequently the primary source of low back pain. Over the past decades, a number of different SI injection techniques have been used in its diagnosis and therapy. Despite the concerns regarding exposure to radiation, image-guided injection techniques are the preferred method to achieve safe and precise intra-articular needle placement. The following study ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 33 7 شماره
صفحات -
تاریخ انتشار 2012