Use of the Heartrail II catheter as a distal stent delivery

ثبت نشده
چکیده

AIMS: The Terumo Heartrail catheter (Terumo Corp., Tokyo, Japan) allows extra deep catheter intubation of coronary vessels and has been shown to be useful in CTO lesions. The aim of this study is to assess the safety and efficacy of using the Heartrail II catheter as a distal stent delivery system in PCI following failure of conventional techniques. METHODS AND RESULTS: We prospectively identified cases performed over a 15-month period in which a Heartrail catheter was used to facilitate stent delivery following failure of conventional techniques. Stent delivery using the Heartrail catheter was performed in 35 cases and was successful in 31 cases. Success rates of 100% in grafts, 95% in RCA, 80% in LAD and 60% in circumflex cases were recorded respectively. Successful stent delivery was associated with intubation depth, with 29/29 succeeding when the intubation depth was > 2 cm and failure in 4/5 cases when the intubation depth <or= 2 cm. There were no complications related to deep intubation of the catheter. CONCLUSIONS: Use of the Heartrail catheter is safe and highly effective for aiding stent delivery across proximal obstructions in both left and right coronary systems. The small number of unsuccessful cases were related to inability of the catheter to traverse stenotic proximal obstructions within 2 cm of the RCA and LCA origins.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Closed External End Double J Catheter as a Nephrostent in Pyeloplasty for Infants with Uretero-Pelvic Junction Obstruction

Uretero-Pelvic Junction Obstruction (UPJO) is a common congenital anomaly that may need pyeloplasty to prevent renal function deterioration. The purpose of this study was to describe a modified use of jj stent catheter in pyeloplasty for infant with UPJO. A series of 12 children, between 3 and 10 months, underwent stenting open pyeloplasty. In each patient a 6 French Foley catheter was placed w...

متن کامل

The "Five-in-Seven" Guiding Technique to Overcome Proximal Coronary Tortuosity During Primary Percutaneous Coronary Intervention

cc This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. A 61-year-old man was admitted for progressively accelerating chest pain during 12 hours....

متن کامل

Unusual Migration of the Distal Catheter of a Ventriculoperitoneal Shunt into the Vagina

Ventriculoperitoneal (VP) shunt is one of the most common pediatric neurosurgical procedures. It has various complications that may have serious consequences such as shunt dysfunction, and unusual migration. Although, migration of shunt catheter to bladder, heart, umbilicus, rectum, pulmonary artery, and stomach has been reported, migration to vagina is a rare one.In this report we present a 16...

متن کامل

Catheter-based delivery of fluid paclitaxel for prevention of restenosis in native coronary artery lesions after stent implantation.

BACKGROUND Stents eluting antiproliferative drugs reduce the incidence of restenosis but delay healing of the vascular wall. We assessed the safety and efficacy of catheter-based local delivery of fluid paclitaxel in patients with coronary de novo stenoses after implantation of a bare metal stent. METHODS AND RESULTS We conducted a prospective, randomized trial comparing the local delivery of...

متن کامل

A Novel Technique for Retrieval of a Drug-Eluting Stent After Catheter Break and Stent Loss

Break of a stent delivery catheter and subsequent stent loss (SL) has been a rare event in the drug-eluting stent (DES) era. We here report a case of successful retrieval of a stent after a break if the delivery catheter and SL from a balloon catheter at a culprit lesion. We finally resolved this situation using a simple balloon technique for both the broken stent catheter inside of the guide c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016