Patient-Specific Fetal Dose Determination for Multi-Target Gamma Knife Radiosurgery: Computational Model and Case Report

نویسندگان

  • Anna K Paulsson
  • Steve Braunstein
  • Justin Phillips
  • Philip V Theodosopoulos
  • Michael McDermott
  • Patricia K Sneed
  • Lijun Ma
چکیده

A 42-year-old woman at 29 weeks gestation via in vitro fertilization who presented with eight metastatic brain lesions received Gamma Knife stereotactic radiosurgery (GKSRS) at our institution. In this study, we report our clinical experience and a general procedure of determining the fetal dose from patient-specific treatment plans and we describe quality assurance measurements to guide the safe practice of multi-target GKSRS of pregnant patients. To estimate fetal dose pre-treatment, peripheral dose-to-focal dose ratios (PFRs) were measured in a phantom at the distance approximating the fundus of uterus. Post-treatment, fetal dose was calculated from the actual patient treatment plan. Quality assurance measurements were carried out via the extrapolation dosimetry method in a head phantom at increasing distances along the longitudinal axis. The measurements were then empirically fitted and the fetal dose was extracted from the curve. The computed and measured fetal dose values were compared with each other and associated radiation risk was estimated. Based on low estimated fetal dose from preliminary phantom measurements, the patient was accepted for GKSRS. Eight brain metastases were treated with prescription doses of 15-19 Gy over 143 min involving all collimator sizes as well as composite sector mixed shots. Direct fetal dose computation based on the actual patient's treatment plan estimated a maximum fetal dose of 0.253 cGy, which was in agreement with surface dose measurements at the level of the patient's uterine fundus during the actual treatment. Later phantom measurements also estimated fetal dose to be in the range of 0.21-0.28 cGy (dose extrapolation curve R2 = 0.998). Using the National Council on Radiation Protection and Measurements (NCRP) population-based model, we estimate the fetal risk of secondary malignancy, which is the primary toxicity after 25 weeks gestation, to be less than 0.01%. Of note, the patient delivered the baby via scheduled cesarean section at 36 weeks without complications attributable to the GKSRS procedure. GKSRS of multiple brain metastases was demonstrated to be safe and feasible during pregnancy. The applicability of a general patient-specific fetal dose determination method was also demonstrated for the first time for such a treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Organ Specific peripheral dose for Gamma knife 4C based on Monte Carlo

Introduction: Stereotactic Gamma Knife radiosurgery has been widely used for treating brain tumors. The scattered radiation outside of treatment field (peripheral dose) can induce the secondary cancer to specific organ. This paper investigated the absorbed dose to eyes, thyroid, heart, lung, breast and colon using a Monte Carlo technique for Mird phantom. We also study the ef...

متن کامل

Long term effects of Gamma knife Radiosurgery for treatment of cerebral arteriovenous malformations

 Abstract Background: The Gamma Knife Radiosurgery (GKR) is an established management option for Cerebral Ar-teriovenous Malformations (AVMS). Therapeutic benefits of radiosurgery for arteriovenous malformations are complete obliteration of nidus with minimal neurological deficit. Methods: Radiosurgery was performed between February 2003 and April 2010 at Kamraniye day clinic, Teh-ran, Iran, us...

متن کامل

Evaluation of the Effects of Inhomogeneities on Dose Profiles Using Polymer Gel Dosimeter and Monte Carlo Simulation in Gamma Knife

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

متن کامل

Whole-procedural Radiological Accuracy for Delivering Multi-session Gamma Knife Radiosurgery With a Relocatable Frame System

A newly developed Gamma Knife relocatable eXtend frame system has enabled the delivery of multi-session Gamma Knife radiosurgery without the use of skull pin fixation frame system. In this study, we investigate and report for the first time the whole procedural radiological accuracy for administering such treatments. To quantify the radiological alignment, the commonly used Winston-Lutz test wa...

متن کامل

Can Gamma Knife Radiosurgery be an Alternative Treatment Modality to Surgery for Vestibular Schwannomas?: A Case Report with Critical Review of the Literature

Development of more sophisticated magnetic resonance imaging scans, the chances of finding asymptomatic patients with vestibular schwannomas as with other intracranial pathologies are increasing. Gamma Knife radiosurgery for vestibular schwannomas has been documented as an efficient and safe procedure based on the treatments in worldwide literature. Preservation of hearing, but not tinnitus, is...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017