Fit-and-fill analysis of trochanteric gamma nail for the Thai proximal femur: a virtual simulation study.

نویسندگان

  • Banchong Mahaisavariya
  • Kriskrai Sitthiseripratip
  • Philip Oris
  • Ekachai Chaichanasiri
  • Jintamai Suwanprateeb
چکیده

The present study present a three-dimensional virtual simulation method to evaluate the fit-and-fill effect of the insertion of a trochanteric gamma nail (TGN) in 98 Thai dadaveric proximal femora. The circular best fit of the 2-dimensional cross-section of the femoral canal and the nail at 4 levels [d100, d120, d140 and d160] which were located at 100, 120, 140 and 160 mm distal to the tip of the greater trochanter were calculated. The evaluation of each level included, 1) the diameters of the medullary canal, 2) the percentage of area filled by the nail in the unreamed medullary canal, 3) the minimal reamer diameter that required enlargement of the canal to accommodate TGN insertion, 4) the minimal inner cortical reaming thickness that needed to be removed, 5) the percentage of cortical bone area that needed to be removed prior to nail insertion and 6) the deviation of the nail center from the center of the medullary canal. The results showed that at 4 studied locations the diameter of unreamed medullary canal averaged 10.3 to 11.8 mm. The nail cross-section that could fill the medullary canal averaged 86.9-95.1%. The minimal reaming diameter for the medullary canal to accommodate the TGN insertion averaged 11.3 to 12.3 mm. The inner cortical thickness that should be removed averaged 0.6 to 0.8 mm. The cortical bone that needed to be removed averaged 13.6 to 19.3% of the total cortical area. The deviation of the nail center from the canal center averaged 0.3 to 0.8 mm. The present study showed some mismatching of the TGN to that of the Thai proximal femur. Appropriate reaming to prepare the medullary canal should be considered prior to TGN insertion to prevent technical problem. Future re-design of the implant may be considered for Thai patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Our experience of management of sub trochanteric fractures of femur by proximal femoral nail

The sub trochanteric zone of the femur is the area extending up till 5 cm distally from the inferior border of the lesser trochanter or the junction of the proximal third and middle third of the femoral shaft. Fracture patterns presenting major displacement in this area are considered sub trochanteric fractures despite their proximal or distal extension. 1 High biomechanical stress concentratio...

متن کامل

Treatment of Unstable Trochanteric Femur Fractures: Proximal Femur Nail Versus Proximal Femur Locking Compression Plate.

Unstable trochanteric femur fractures are common fractures that are difficult to manage. We conducted a prospective study to compare functional outcomes and complications of 2 different implant designs, proximal femur nail (PFN) and proximal femur locking compression plate (PFLCP), used in internal fixation of unstable trochanteric femur fractures. On hospital admission, 48 patients with unstab...

متن کامل

Complications in Treatment of 31-A Fractures with Trochanteric Gamma Nail (TGN) Versus Gamma3 Nail (G3N) - A Review of 217 Cases

INTRODUCTION The aim of this study was to clinically evaluate two generations of intramedullary gamma-nail used in the treatment of 31-A femur fractures. MATERIALS AND METHODS In two consecutive series, 117 trochanteric gamma nails (TGN) and 100 Gamma3 nails (G3N) were implanted for the treatment of inter- and subtrochanteric fractures between 2009 and 2011. Clinical and radiological follow-u...

متن کامل

Biomechanical comparison of dynamic hip screw and Gamma nail for the treatment of unstable trochanteric fractures: a finite element study

Objectives: To investigate the biomechanical behavior of the femur with two different implant configurations, namely dynamic hip screw and Gamma nail, in the treatment of two types of unstable intertrochanteric femoral fracture. Methods: A 3D finite element model of the intact proximal femur was constructed, from which two types of fractured models (AO classification 31-A2 and 31-A3) were produ...

متن کامل

Breakage of a Third Generation Gamma Nail: A Case Report and Review of the Literature

The use of intramedullary nails to treat trochanteric fractures of the femur has increased with the increasing size of the elderly population. The third generation Gamma nail is currently one of the most popular devices for the treatment of trochanteric fractures. Nail breakage is a rare complication, possibly resulting from fatigue fracture of the implant. We present the first reported case of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Medical Association of Thailand = Chotmaihet thangphaet

دوره 87 11  شماره 

صفحات  -

تاریخ انتشار 2004