CT-guided aspirations in the head and neck: assessment of the first 216 cases.

نویسندگان

  • Paul M Sherman
  • David M Yousem
  • Laurie A Loevner
چکیده

BACKGROUND AND PURPOSE The growth of cross-sectional imaging has increased the detection of nonpalpable head and neck masses. We sought to determine the reliability of CT-guided fine-needle aspiration (FNA) over 216 consecutive cases. METHODS We retrospectively reviewed histopathologic findings and notes from 216 consecutive head and neck CT-guided FNA procedures performed between 1993 and 2003. Types of needles used, passes required, lesion location, initial cytologic diagnosis, and final histopathologic or clinical diagnosis were reviewed. RESULTS Diagnostic samples were obtained in 195 (90.3%) of the lesions, with 21 (9.7%) inadequate samples. A correct diagnosis was made in 191 cases (88.4%). Final FNA diagnosis was discordant in four (1.9%) specimens, with the parapharyngeal space and parotid gland having the highest rate of inaccuracy. The range in number of passes required for final diagnosis was one to six (mode, 2.0 passes per specimen; median, 2.0; mean, 2.6; standard deviation, 1.13). In 135 (63%) of 216 cases, definitive surgical pathologic results, including findings for the four discordant specimens, were obtained. Of the nondiagnostic specimens, six (29%) of 21 went to surgery, five (83%) of six were neoplastic, and one (17%) of six was fibrous tissue. The remainder underwent clinical and imaging follow-up. CONCLUSION CT-guided FNA is a safe, well tolerated, and accurate for the diagnosis of head and neck lesions. In our series, the percentage of diagnostic samples obtained improved compared with prior reports. The low diagnostic error rate overall was possibly related to onsite evaluation by the cytopathologist and to improved FNA technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endoscopic management of cerebrospinal fluid rhinorrhea from anterior skull base defects

  Abstract   Background: Over the past 20 years, the minimally invasive endoscopic approach   has gained widespread acceptance. The study was performed to evaluate the   diagnostic method and the success rate of endoscopically diagnosed and treated CSF   rhinorrhea, and also investigations such as leakage site and etiologic factor.   Methods: This retrospective CSF leakage management review of ...

متن کامل

Thyroid dose and dose reduction method from CT scan of head and neck

Introduction: Computed tomography (CT) consists of 11% of all imaging methods, but accounts for approximately 67% of radiation exposure due to diagnostic cases. More than one-third of all CT scans are done in the head and neck area. The thyroid gland is irradiated during CT head and neck. According to studies, this gland has the highest levels of radiation-induced cancer, and i...

متن کامل

Synovial Sarcoma of the Head and Neck: A Case of Childhood Soft Tissue Sarcoma

Although rare, synovial sarcoma is the most common malignant non-rhabdomyosarcomatous soft tissue sarcoma in children and adolescents. Synovial sarcoma typically involves the soft tissues of the extremities, especially near large joints, but it can occur anywhere in the body in locations far from joint spaces. Although this tumor typically affects adults in their fourth decade of life, nearly h...

متن کامل

Solitary Head and Neck Cysticercosis: A Series of Rare Cases

Introduction: Cysticercosis is a disease which is caused by the infestation of the larvae Taenia solium, with humans acting as an intermediate host instead of a definitive host. Head and neck involvement including maxillofacial and oral involvement of cysticercosis is quite rare.  Case Report: We report a series of rare cases of cysticercosis of the head and neck region encountered in a tertia...

متن کامل

Assessment of Radiation Dose to the Lens of the Eye and Thyroid of Patients Undergoing Head and Neck Computed Tomography at Five Hospitals in Mashhad, Iran

Introduction: In recent years, the number of computed tomography (CT) scans, which is a high-dose technique, has increased significantly. Head and neck CT is performed frequently and thyroid, particularly in children, has always been considered a sensitive organ. In recent years, radiobiologists and health physicists have been more concerned about the safety of lenses of the eyes, as cataract i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 25 9  شماره 

صفحات  -

تاریخ انتشار 2004