Computed tomography (CT) devices are routinely employed to obtain three-dimensional images of the human body. The reconstructed CT numbers represent weighted x-ray attenuation coefficients. Their spectral weighting is influenced by the selected x-ray source spectrum, the detector characteristics, and the attenuating object itself. The quantitative ground truth of the scanned object is given by the spectral attenuation coefficient. It is not directly measurable in standard CT. For spectral CT measurements, algorithms like the basis material decomposition yield parametrized representations of the spectral mass attenuation coefficient. In practical applications, image-based formulations are commonly used. They are affected by both the CT system characteristics and the object self-attenuation effects. In this article the authors introduce an image-based spectral CT method. It expresses measured CT data as a spectral integration of the spectral attenuation coefficient multiplied by a local weighting function (LWF). The LWF represents the local energy weighting in the image domain, taking into account the system and reconstruction properties and the object self-attenuation. A generalized image-based formulation of spectral CT algorithms is obtained, with no need for additional corrections of, e.g., beam hardening. The iterative procedure called local spectral reconstruction yields both the mass attenuation coefficients of the object and a representation of the LWF. The quantitative accuracy and precision of the method are investigated in several applications: First, beam hardening corrections to various target energy weightings and attenuation correction maps for SPECT/CT and PET/CT are calculated. Second, an iodine density evaluation is performed. Finally, a direct identification of spectral attenuation functions using the LWF result is demonstrated. In all applications, the ground truth of the objects is reproduced with a quantitative accuracy in the subpercent to 2% range. An exponential convergence behavior of the iterative procedure is observed, with one to two iteration steps as a good compromise between quantitative accuracy and precision. The authors conclude that the method can be used to perform image-based spectral CT reconstructions with quantitative accuracy. Existing algorithms benefit from the intrinsic treatment of beam hardening and system properties. Novel algorithms are enabled to directly compare material model functions to spectral measurement data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography

Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...

متن کامل

Evaluation of Metal Artifact Reduction software in Computed Tomography

Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...

متن کامل

Image Optimization in Single Photon Emission Computed Tomography by Hardware Modifications with Monte Carlo Simulation

Introduction: In Single Photon Emission Computed Tomography (SPECT), the projection data used for image reconstruction are distorted by several factors, including attenuation and scattering of gamma rays, collimator structure, data acquisition method, organ motion, and washout of radiopharmaceuticals. All these make reconstruction of a quantitative SPECT image very difficult. Simulation of a SP...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 36 10  شماره 

صفحات  -

تاریخ انتشار 2009