EMF [ mV ] t EMF [ mV ] t CALIBRATION CURVE FOR CATION I CATION INTERFERENCE CALIBRATION CURVE

نویسندگان

  • Urs Oesch
  • Daniel Ammann
  • Wilhelm Simon
چکیده

Among the techniques of detection used in clinical chemistry, optical and electrochemical methods are especially attractive. However, except for glass electrodes for pH measurement, potentiometric electrochemical sensors (ionselective electrodes) gained general acceptance in clinical analyzers and in clinical instrumentation, respectively, only around 1970 (for reviews see 1-5). Here we report on the state of the art in the design of membranes for clinically relevant ion-selective electrodes (ISE’s) and on possible trends in their development.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparation of a novel iodide-selective electrode based on iodide-miconazole ion-pair and its application to pharmaceutical analysis.

An iodide-miconazole ion-paired complex was used as a suitable ion-exchanger for the preparation of a plasticized-PVC membrane electrode. Among different solvent mediators tested, dioctylsebacate exhibited the proper response characteristics, including Nernstian slope of the calibration curve, fast response time and good reproducibility of the emf values. The electrode exhibits a Nernstian slop...

متن کامل

Exposure to Extremely Low-Frequency Electromagnetic Fields Modulates Na+ Currents in Rat Cerebellar Granule Cells through Increase of AA/PGE2 and EP Receptor-Mediated cAMP/PKA Pathway

Although the modulation of Ca(2+) channel activity by extremely low-frequency electromagnetic fields (ELF-EMF) has been studied previously, few reports have addressed the effects of such fields on the activity of voltage-activated Na(+) channels (Na(v)). Here, we investigated the effects of ELF-EMF on Na(v) activity in rat cerebellar granule cells (GCs). Our results reveal that exposing cerebel...

متن کامل

An investigation into factors affecting electron density calibration for a megavoltage cone‐beam CT system

There is a growing interest in the use of megavoltage cone-beam computed tomography (MV CBCT) data for radiotherapy treatment planning. To calculate accurate dose distributions, knowledge of the electron density (ED) of the tissues being irradiated is required. In the case of MV CBCT, it is necessary to determine a calibration-relating CT number to ED, utilizing the photon beam produced for MV ...

متن کامل

Towards an automated, standardized protocol for determination of equilibrium potential of ion-selective electrodes.

An automated real-time method for determination of ISE steady state value and response time is developed, following most recent IUPAC recommendations. Specifically, detection of the 'steady state' is related to (1) the time derivative of the emf as it reaches a limiting value (ΔE/Δt(limit), e.g., 0.1-1.0 mV min(-1)) and (2) the duration of time for which the absolute value of the time derivativ...

متن کامل

A New Solution for Shock and Vibration Calibration of Accelerometers

Shock and vibration phenomena are present around us in everything that moves. The accelerometer is a class of instruments commonly used to measure that motion, producing an electrical output signal related to the applied motion. Accurate accelerometer calibration is a way to provide physical meaning to this electrical output and it is a prerequisite for quality motion measurements. Systems and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004