Results of a European dose survey for mammography.

نویسندگان

  • K Michielsen
  • J Jacobs
  • K Lemmens
  • J Nens
  • J Zoetelief
  • K Faulkner
  • H Bosmans
چکیده

For the dose study, a semi-automated method of data collection is used in this study. The participating centres were asked to fill out a spreadsheet with all necessary data and return it. For direct digital (DR) systems, the relevant data available in the DICOM header were used. All data is automatically added to a database and processed. The data were used to calculate the mean glandular dose for every image and for different thicknesses of polymethyl methacrylate phantoms using available conversion factors. Second-degree polynomials were fitted to the patient dose data and a reference dose curve was constructed for a range of thicknesses instead of a dose reference level at a single point. The dose reference curve rises from 1.57 mGy for a thickness of 30 mm to 2.50 mGy for 55 mm and 3.83 mGy for 75 mm. The results show centres that exceed this curve lie only in the lower or higher range of thicknesses and would remain undetected using a dose reference value in a single point. This gives better information to radiographers on where there is room for improvement of the dose levels in their system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculation of Absorbed Glandular Dose using a FORTRAN Program Based on Monte Carlo X-ray Spectra in Mammography

Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...

متن کامل

Breast dose in conventional and digital mamography

Introduction: The amount of doses received in mammography is one of the biggest concerns in the world. According to some statistics, every 12 minutes a woman dies due to breast cancer. Mammography concerned to detect breast cancer at an early stage of the disease as well as for screening, however due to the risk of exposure, the increasingly and widespread use of mammography fo...

متن کامل

Determination of Average Glandular Dose in Mammography for Rh-Rh Mammogram Using Sobol-Wu Parameters in FORTRAN Code

Introduction: To write a computational program to calculate the average glandular dose in Mammography with Rh-Rh target-filter and also use it as an accurate and fast method of dose calculation founder different situations. Materials and Methods: In this research, the Sobol-Wu parameters are used to write a FORTRAN code for glandular dose calculation in Rh-Rh target-filter mammograms. The code ...

متن کامل

ارزیابی دز و کیفیت تصویر در آزمون های ماموگرافی در مراکز ماموگرافی شهر تهران

Abstract Background: Breast cancer is one of the most common form of cancer among women. Diagnosis in the early stage of emergence is the most effective way to reduce the mortality caused by this disease. Mammography, the safest and most accurate imaging test for the identification of breast cancer, required high quality images along applying the lowest possible dose to sensitive tissues of the...

متن کامل

Estimation of Mean Estimation of Mean Glandular Dose in Mammography Examination in some of Radiology Centers in Tehran city

Introduction: the objectives of this research were determination of Mean Glandular Dose in film- screen and digital mammography examinations, estimation of accumulated effective dose in some of mammography centers in Tehran city and estimating cancer risk due to these examinations. Materials and Methods: the clinical data were collected from the 1318 <...

متن کامل

Designing a shield to reduce radiation dose during mammography: Dosimetric evaluation

Background: This paper presents a method to reduce radiation exposure during mammography by analysing the doses to ipsilateral and contralateral breasts and to adjacent organs by evaluating material-dependent shielding performance.  Materials and Methods: Six target-filter combinations (Mo-Mo, Mo-Rh, Rh-Rh, Rh-Mo, W-Mo, W-Rh) were tested by measuring the doses delivered to the breasts and adjac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 129 1-3  شماره 

صفحات  -

تاریخ انتشار 2008