The suitability of an uncemented hydroxyapatite coated (HAC) hip hemiarthroplasty stem for intra-capsular femoral neck fractures in osteoporotic elderly patients: the Metaphyseal-Diaphyseal index, a solution to preventing intra-operative periprosthetic fracture
نویسندگان
چکیده
This study will seek to identify a measurable radiographic index, the Metaphyseal-Diaphyseal Index (MDI) score to determine whether intra-operative fracture in osteoporotic bone can be predicted.A 5 year prospective cohort of 560 consecutive patients, undergoing hemiarthroplasty (cemented or uncemented), was evaluated. A nested case-control study to determine risk factors affecting intra-operative fracture was carried out. The Vancouver Classification was used to classify periprosthetic fracture. The MDI score was calculated using radiographs from the uncemented group. As a control (gold standard), Yeung et al's Canal Bone Ratio (CBR) score was also calculated. From this, a receiver operating characteristic (ROC) curve was formulated for both scores and area under the curve (AUC) compared. Intra and inter-observer correlations were determined. Cost analysis was also worked out for adverse outcomes. Four hundred and seven uncemented and one hundred and fifty-three cemented stems were implanted. The use of uncemented implants was the main risk factor for intra-operative periprosthetic fracture. Sixty-two periprosthetic fractures occurred in the uncemented group (15.2%), nine occurred in the cemented group (5.9%), P < 0.001. The revision rate for sustaining a periprosthetic fracture (uncemented group) was 17.7%, P < 0.001 and 90 day mortality 19.7%, P < 0.03. MDI's AUC was 0.985 compared to CBR's 0.948, P < 0.001. The MDI score cut-off to predict fracture was 21, sensitivity 98.3%, specificity 99.8%, positive predictive value 90.5% and negative predictive value 98%. Multivariate regression analysis ruled out any other confounding factors as being significant. The intra and inter-observer Pearson correlation scores were r = 0.99, P < 0.001. JRI uncemented hemiarthroplasty has a significantly higher intra-operative fracture rate. We recommend cemented arthroplasty for hip fractures. We propose a radiographic system that may allow surgeons to select patients who are good candidates for uncemented arthroplasty, but it needs prospective validation.
منابع مشابه
Association of intra-operative metaphyseal fractures with prosthesis size during hemiarthroplasty of the hip.
PURPOSE To study the possible causes of intra-operative metaphyseal fractures in elderly patients undergoing hemiarthroplasty for displaced intracapsular femoral neck fracture. METHODS 36 men and 228 women aged 61 to 89 years with 273 displaced femoral neck fractures underwent hemiarthroplasty using a hydroxyapatite ceramic-coated Furlong bipolar prosthesis. Anteroposterior and lateral radiog...
متن کاملEpidemiology of periprosthetic femoral fractures in 5417 revision total hip arthroplasties: a 40-year experience.
AIMS The goals of this study were to define the risk factors, characteristics, and chronology of fractures in 5417 revision total hip arthroplasties (THAs). PATIENTS AND METHODS From our hospital's prospectively collected database we identified all patients who had undergone a revision THA between 1969 and 2011 which involved the femoral stem. The patients' medical records and radiographs wer...
متن کاملUncemented fully hydroxyapatite-coated hip stem for intracapsular femoral neck fractures in osteoporotic elderly patients: a multicenter study
There is still debate over the limits of age and bone stock quality of patients on whom to use an un-cemented straight stem coated with hydroxyapatite (HA). We studied a group of 244 patients with a displaced intracapsular fracture of the femoral neck who underwent cementless hemiarthroplasty or total hip arthroplasty. 143 patients were reviewed at the two-year follow up. A fully HA-coated stem...
متن کاملFixation of the fully hydroxyapatite-coated Corail stem implanted due to femoral neck fracture
BACKGROUND Today, dislocated femoral neck fractures are commonly treated with a cemented hip arthroplasty. However, cementing of the femoral component may lead to adverse effects and even death. Uncemented stems may lower these risks and hydroxyapatite (HA) coating may enhance integration, but prosthetic stability and clinical outcome in patients with osteoporotic bone have not been fully explo...
متن کاملMid term results of Furlong LOL uncemented hip hemiarthroplasty for fractures of the femoral neck.
We report the mid-term results of hemiarthroplasty with the Furlong hydroxyapatite coated bipolar prosthesis for displaced (Garden type III and IV) intracapsular hip fracture in 480 patients operated between 1989 and 2000. Three hundred sixty eight (77%) patients were lost to follow-up due to death, dementia or movement away from the area. In the patients followed up there was an 8% reoperation...
متن کامل