Reduction of Metal Artifacts in Patients with Hip Joint Implants by Using Optimized Imaging Protocols
نویسندگان
چکیده
Introduction: Metal-on-metal (MOM) hip resurfacing implants were predicted to be suitable for young, active patients (1). However, there are indications that the MOM-implants fail more frequently than traditional implants (2), possibly caused by an aseptic lymphocytic vasculitis-associated lesion in the tissues surrounding the implant (3). The diagnosis of these lesions by MRI would be facilitated by artifact-reducing protocols, which have been outlined recently (3-5). The purpose of this study was to investigate to which extent metal artifacts can be reduced, in the worst case of a stainless steel implant, by optimizing routine imaging protocols, without resorting to special pulse sequences not widely available.
منابع مشابه
Evaluation of Metal Artifact Reduction software in Computed Tomography
Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملSlice Encoding for Metal Artefact Correction in magnetic resonance imaging examinations for radiotherapy planning
BACKGROUND AND PURPOSE Magnetic resonance (MR) and computed tomography (CT) images are degraded in the presence of metallic implants. We investigate whether SEMAC (Slice Encoding for Metal Artifact Correction) MR is advantageous for radiotherapy (RT) planning. METHODS Conventional and SEMAC MR protocols were compared (1.5T). A spine fixation device suspended in gelatine, two patients with spi...
متن کاملFinite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions
Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...
متن کاملX-ray CT metal artifact reduction using wavelet domain L0 sparse regularization.
X-ray computed tomography (CT) imaging of patients with metallic implants usually suffers from streaking metal artifacts. In this paper, we propose a new projection completion metal artifact reduction (MAR) algorithm by formulating the completion of missing projections as a regularized inverse problem in the wavelet domain. The Douglas-Rachford splitting (DRS) algorithm was used to iteratively ...