Culture Positivity of CVCs Used for TPN: Investigation of an Association with Catheter-Related Infection and Comparison of Causative Organisms between ICU and Non-ICU CVCs
نویسندگان
چکیده
A relationship between central venous catheter (CVC) tip colonisation and catheter-related blood-stream infection (CRBSI) has been suggested. We examined culture positivity of CVC tips (colonised and infected CVCs) in a total parenteral nutrition (TPN) population. Our aims were to define the relationship between culture positivity and CRBSI, and to compare causative organisms between culture positive and CRBSI CVCS, and between ward and ICU CVCs. All patients receiving TPN via non-tunnelled CVCs during the study (1997-2009) were included. All CVC tips were analysed. Data were collated contemporaneously. A TPN audit committee determined whether CVC tip culture positivity reflected colonisation/CRBSI using CDC criteria. 1,392 patients received TPN via 2,565 CVCs over 15,397 CVC days. 25.4% of CVCs tips were culture positive, of these 32% developed CRBSI. There was a nonsignificant trend of higher Gram negative Bacilli isolation in ICU CVCs (P = 0.1), ward CVCs were associated with higher rates of staphylococcal isolation (P = 0.01). A similar pattern of organisms were cultured from CRBSI and culture positive CVCs. The consistent relationship between CRBSI and culture positive CVCs, and similar pattern of causative organisms further supports an aetiological relationship between culture positive CVC tips and CRBSI, supporting the contention that CVC culture-positivity may be a useful surrogate marker for CRBSI rates.
منابع مشابه
More Effective Prevention of Incompatibility Reactions Through the Use of Four Lumen Central Venous Catheters in Critically Ill Patients
We evaluated potential practical benefits of the use of four lumen central venous catheters (CVCs) in critically ill patients in intensive care units (ICUs). Intensive care specialists assessed ease of handling during catheter insertion and ICU nurses determined whether adequate flow rates can be achieved with four lumen CVCs. We also determined to what extent strictly dedicated medication lume...
متن کاملCentral venous catheter-related blood stream infections: incidence and an analysis of risk factors.
Six hundred and fifty-five central venous catheters (CVC) in 496 patients in the intensive care unit of Hospital Sultanah Aminah were studied to determine the incidence and risk factors for central venous catheter-related blood stream infection (CR-BSI). CR-BSI was diagnosed in 38 catheters, giving an incidence of 9.43 CR-BSI per 1000 catheter days. The mean duration in situ was 8.4 +/- 4.9 day...
متن کاملSkin fold technique for central venous catheter fixation; Comparison with conventional method for postopration infections
Background: Central Venous Catheters (CVCs) are used not only as a tool to access to central venous system, but also for hemodynamic monitoring, parenteral nutrition, chemotherapy and hemodialysis. The use of CVCs is associated with some complications notably infections that are troublesome both to patient and physician. We conducted this study to examine catheter fixation with skin fold techni...
متن کاملPrevalence of the use of central venous access devices within and outside of the intensive care unit: results of a survey among hospitals in the prevention epicenter program of the Centers for Disease Control and Prevention.
OBJECTIVE To determine the prevalence of central venous catheter (CVC) use among patients both within and outside the ICU setting. DESIGN A 1-day prevalence survey of CVC use among adult inpatients at six medical centers participating in the Prevention Epicenter Program of the CDC. Using a standardized form, observers at each Epicenter performed a hospital-wide survey, collecting data on CVC ...
متن کاملThe microbiological and clinical outcome of guide wire exchanged versus newly inserted antimicrobial surface treated central venous catheters
INTRODUCTION The management of suspected central venous catheter (CVC)-related sepsis by guide wire exchange (GWX) is not recommended. However, GWX for new antimicrobial surface treated (AST) triple lumen CVCs has never been studied. We aimed to compare the microbiological outcome of triple lumen AST CVCs inserted by GWX (GWX-CVCs) with newly inserted triple lumen AST CVCs (NI-CVCs). METHODS ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2012 شماره
صفحات -
تاریخ انتشار 2012