Monte Carlo modelling of a-Si EPID response: the effect of spectral variations with field size and position.
نویسندگان
چکیده
This study focused on predicting the electronic portal imaging device (EPID) image of intensity modulated radiation treatment (IMRT) fields in the absence of attenuation material in the beam with Monte Carlo methods. As IMRT treatments consist of a series of segments of various sizes that are not always delivered on the central axis, large spectral variations may be observed between the segments. The effect of these spectral variations on the EPID response was studied with fields of various sizes and off-axis positions. A detailed description of the EPID was implemented in a Monte Carlo model. The EPID model was validated by comparing the EPID output factors for field sizes between 1 x 1 and 26 x 26 cm2 at the isocenter. The Monte Carlo simulations agreed with the measurements to within 1.5%. The Monte Carlo model succeeded in predicting the EPID response at the center of the fields of various sizes and offsets to within 1% of the measurements. Large variations (up to 29%) of the EPID response were observed between the various offsets. The EPID response increased with field size and with field offset for most cases. The Monte Carlo model was then used to predict the image of a simple test IMRT field delivered on the beam axis and with an offset. A variation of EPID response up to 28% was found between the on- and off-axis delivery. Finally, two clinical IMRT fields were simulated and compared to the measurements. For all IMRT fields, simulations and measurements agreed within 3%-0.2 cm for 98% of the pixels. The spectral variations were quantified by extracting from the spectra at the center of the fields the total photon yield (Ytotal), the photon yield below 1 MeV (Ylow), and the percentage of photons below 1 MeV (Plow). For the studied cases, a correlation was shown between the EPID response variation and Ytotal, Ylow, and Plow.
منابع مشابه
Monte Carlo simulation of the transit dosimetric response of an a-Si electronic portal imaging device
Amorphous silicon (a-Si) electronic portal imaging devices (EPIDs) are x-ray detectors frequently used in radiotherapy imaging and dosimetry applications. EPIDs employ a copper plate and gadolinium oxysulfide phosphor screen with an array of a-Si photodiodes to indirectly detect incident radiation. In this study, a previously developed Monte Carlo (MC) model of an aSi EPID has been extended for...
متن کاملThe Effect of Si Substitution on Distribution of H2 on Coronene
In this work, the radial distribution function (RDF) of H2 adsorption on coronene (C24) and its Si Substituted forms was investigated by Monte Carlo method. The effect of number and position of silicon substituent on the Coronene (C24) was compared. The maximum value of RDF at 298 K and 0.1 MPa is 4.34 for 18 Si, A structure at 0.73 Å. On the basis of results, t...
متن کاملEPID in vivo Dosimetry
Introduction: The most modern radiotherapy devices are equipped with an Electronic Portal Imaging Device (EPID) system which is located on opposite side of the machine’s head. EPID system is often used to setting up the position verification during or between radiotherapy sessions. Material and Methods: Various types of dosimeters have been used to setting up ...
متن کاملRadiotherapy treatment verification using radiological thickness measured with an amorphous silicon electronic portal imaging device: Monte Carlo simulation and experiment.
This work validates the use of an amorphous-silicon, flat-panel electronic portal imaging device (a-Si EPID) for use as a gauge of patient or phantom radiological thickness, as an alternative to dosimetry. The response of the a-Si EPID is calibrated by adapting a technique previously applied to scanning liquid ion chamber EPIDs, and the stability, accuracy and reliability of this calibration ar...
متن کاملEffect of the radiation field of view and angle in unconventional angiography on patient doses: a Monte Carlo simulation study using a voxelized phantom
Introduction: We aimed to investigate the effect of variation of beam angle and field of view (FOV) on organs’ and effective doses for patients undergoing interventional cardiology examinations by using Monte Carlo simulations and ICRP110 phantom. Materials and Methods: Simulations were done for energies obtained from experimental measurements on the left...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 33 12 شماره
صفحات -
تاریخ انتشار 2006