Quadratic Regularization Design for Fan Beam Transmission Tomography
نویسندگان
چکیده
Statistical methods for tomographic image reconstruction have shown considerable potential for improving image quality in X-ray CT. Penalized-likelihood (PL) image reconstruction methods require maximizing an objective function that is based on the log-likelihood of the sinogram measurements and on a roughness penalty function to control noise. In transmission tomography, PL methods (and MAP methods) based on conventional quadratic regularization functions lead to nonuniform and anisotropic spatial resolution, even for idealized shift-invariant imaging systems. We have previously addressed this problem for parallel-beam emission tomography by designing data-dependent, shift-variant regularizers that improve resolution uniformity. This paper extends those methods to the fan-beam geometry used in X-ray CT imaging. Simulation results demonstrate that the new method for regularization design requires very modest computation and leads to nearly uniform and isotropic spatial resolution in the fan-beam geometry when using quadratic regularization.
منابع مشابه
Usability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter
Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...
متن کاملHigh-order Total Variation Regularization Approach for Axially Symmetric Object Tomography from a Single Radiograph
In this paper, we consider tomographic reconstruction for axially symmetric objects from a single radiograph formed by fan-beam X-rays. All contemporary methods are based on the assumption that the density is piecewise constant or linear. From a practical viewpoint, this is quite a restrictive approximation. The method we propose is based on high-order total variation regularization. Its main a...
متن کاملStatistical X-ray Computed Tomography Image Reconstruction with Beam Hardening Correction
This paper describes two statistical iterative reconstruction methods for X-ray CT. The rst method assumes a mono-energetic model for X-ray attenuation. We approximate the transmission Poisson likelihood by a quadratic cost function and exploit its convexity to derive a separable quadratic surrogate function that is easily minimized using parallelizable algorithms. Ordered subsets are used to a...
متن کاملQuadratic Regularization Design for 3D Axial CT
While iterative reconstruction (IR) methods have potential advantages over conventional FBP reconstruction such as reduced patient dose and improved noise properties, their use of statistical weighting and space variant scanning geometries can lead to nonuniform and anisotropic spatial resolution. Due to the large number of voxels in the image volume, regularization design methods based on disc...
متن کاملSoft-Tissue Imaging in Low-Dose, C-Arm Cone-Beam CT Using Statistical Image Reconstruction
C-arm cone-beam CT (CBCT) is an emerging tool for intraoperative imaging, but current embodiments exhibit modest soft-tissue imaging capability and are largely constrained to high-contrast imaging tasks. A major advance in image quality is facilitated by statistical iterative reconstruction techniques. This work adapts a general penalized likelihood (PL) reconstruction approach with variable pe...
متن کامل