Partial liquid ventilation: effects of liquid volume and ventilatory settings on perfluorocarbon evaporation.
نویسندگان
چکیده
During partial liquid ventilation perfluorocarbons are eliminated mainly by evaporation via the airways. The effects of intrapulmonary perfluorocarbon volume, respiratory rate, tidal volume, as well as the level of end-expiratory pressure on perfluorocarbon elimination from isolated lungs, were studied. Nonperfused rabbit lungs underwent partial liquid ventilation (2-15 mL x kg(-1) perfluorocarbon) with variable levels of end-expiratory pressure (0-10 cmH2O), respiratory rates (15-60 breaths x min(-1)) and tidal volumes (3.3-10.0 mL x kg(-1)). Evaporative loss of perfluorocarbon was determined gravimetrically as rate of change in lung weight. At constant respiratory settings, intrapulmonary liquid volume determined evaporative loss in a nonlinear fashion. Mean evaporation at a liquid volume of 5 mL x kg(-1) was 13% lower compared to evaporation at a liquid volume of 15 mL x kg(-1). Any increase in end-expiratory pressure reduced perfluorocarbon evaporation, e.g. by approximately 50% when end-expiratory pressure was increased from 0 to 10 cmH2O. At constant end-expiratory pressure and perfluorocarbon filling evaporation increased in a linear fashion with increasing respiratory rate and tidal volume. In summary, the experiments suggested that evaporative loss of perfluorocarbons during partial liquid ventilation of isolated lungs is increased with increasing intrapulmonary liquid volume, respiratory rate and tidal volume and is reduced in a level-dependent fashion by the application of positive end-expiratory pressure.
منابع مشابه
A Morphometric Model of Airway Mechanics and Gas Transfer during Neonatal Tidal Liquid Ventilation
INTRODUCTION The great development and diffusion of Liquid Assisted Ventilation (LAV) techniques (perfluorocarbon (PFC) lavage, Tidal Liquid Ventilation (TLV), and Partial Liquid Ventilation (PLV)) [1] is mainly due to the benefits they provide to patients with respect to other methods of ventilatory support. Such benefits derive from eliminating the liquid-gas interface in the alveoli. In fact...
متن کاملThe use of chilled condensers for the recovery of perfluorocarbon liquid in an experimental model of perfluorocarbon vapour loss during neonatal partial liquid ventilation
BACKGROUND Perfluorocarbon (PFC) vapour in the expired gases during partial liquid ventilation should be prevented from entering the atmosphere and recovered for potential reuse. This study aimed to determine how much PFC liquid could be recovered using a conventional humidified neonatal ventilator with chilled condensers in place of the usual expiratory ventilator circuit and whether PFC liqui...
متن کاملLiquid ventilation innovations in ventilatory management.
The goal of mechanical ventilation is to maintain adequate gas exchange by opening and stabilizing alveolar units with minimal detriment to the pulmonary and circulatory systems. The optimal ventilatory strategy may be difficult to achieve, especially in patients with respiratory failure. Total liquid ventilation is a process whereby a liquid perfluorocarbon (PFC) replaces both the functional r...
متن کاملAn advanced expiratory circuit for the recovery of perfluorocarbon liquid from non-saturated perfluorocarbon vapour during partial liquid ventilation: an experimental model
BACKGROUND The loss of perfluorocarbon (PFC) vapour in the expired gases during partial liquid ventilation should be minimized both to prevent perfluorocarbon vapour entering the atmosphere and to re-use the recovered PFC liquid. Using a substantially modified design of our previously described condenser, we aimed to determine how much perfluorocarbon liquid could be recovered from gases contai...
متن کاملPartial liquid ventilation improves gas exchange and increases EELV in acute lung injury.
Gas exchange is improved during partial liquid ventilation with perfluorocarbon in animal models of acute lung injury. The specific mechanisms are unproved. We measured end-expiratory lung volume (EELV) by null-point body plethysmography in anesthetized sheep. Measurements of gas exchange and EELV were made before and after acute lung injury was induced with intravenous oleic acid to decrease E...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 20 6 شماره
صفحات -
تاریخ انتشار 2002