The suitability of Tedlar bags for breath sampling in medical diagnostic research.
نویسندگان
چکیده
Tedlar bags are tested for their suitability for breath sampling for medical diagnostic purposes. Proton-transfer reaction-mass spectrometry was used to monitor the changes in composition of various mixtures contained in custom-made black-layered Tedlar bags. Characteristic ions at m/z 88 and 95 amu reflect considerable pollution from the bag material. The pollutant found on m/z 88 amu is most probably N,N-dimethylacetamide, a latent solvent used in the production of Tedlar film. Gas composition losses during filling were found to range from 5 to 47%, depending on the compound. Once stored, the half-lives of methanol, acetaldehyde, acetone, isoprene, benzene, toluene and styrene were estimated between 5 and 13 days. Losses from breath samples (52 h after filling) were found to be less than 10%. No observable decrease was found for ethylene over 3 days, using laser-based photoacoustic detection. For the use of Tedlar bags, a standardized protocol is advised, where the time point of analysis is fixed for all samples and should be kept as close as possible to the time of sampling.
منابع مشابه
Some Insights into Analytical Bias Involved in the Application of Grab Sampling for Volatile Organic Compounds: A Case Study against Used Tedlar Bags
In this study, we have examined the patterns of VOCs released from used Tedlar bags that were once used for the collection under strong source activities. In this way, we attempted to account for the possible bias associated with the repetitive use of Tedlar bags. To this end, we selected the bags that were never heated. All of these target bags were used in ambient temperature (typically at or...
متن کاملStability of odorants from pig production in sampling bags for olfactometry.
Odor from pig production facilities is typically measured with olfactometry, whereby odor samples are collected in sampling bags and assessed by human panelists within 30 h. In the present study, the storage stability of odorants in two types of sampling bags that are often used for olfactometry was investigated. The bags were made of Tedlar or Nalophan. In a field experiment, humid and dried a...
متن کاملBias of Tedlar bags in the measurement of agricultural odorants.
Odor regulations typically specify the use of dynamic dilution olfactometery (DDO) as a method to quantify odor emissions, and Tedlar bags are the preferred holding container for grab samples. This study was conducted to determine if Tedlar bags affect the integrity of sampled air from animal operations. Air samples were collected simultaneously in both Tedlar bags and Tenax thermal desorption ...
متن کاملDetection of 2-pentylfuran in the breath of patients with Aspergillus fumigatus.
Aspergillus fumigatus produces 2-pentylfuran (2-PF) when cultured on blood agar, nutrient agar and other media. As 2-PF is not known to be produced by mammalian metabolism we hypothesized that it is detectable in breath of patients colonized or infected with A. fumigatus. Breath was tested for 2-PF from normal subjects, those undergoing chemotherapy, and adults at risk of colonization or infect...
متن کاملتجزیه آلکانها و آلدئیدهای درونزاد در هوای بازدم شاغلین در مواجهه با غبار حاوی سیلیس
Background & Objectives : Silica is one of the most air pollutant in workplaces which long-term occupational exposure to silica is associated with an increased risk for respiratory diseases such as silicosis. Silicosis is an oxidative stress related disease and can lead to the development of lung cancer. This study aims to analysis of endogenous alkanes and aldehydes in the exhaled breath...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physiological measurement
دوره 28 1 شماره
صفحات -
تاریخ انتشار 2007