International normalized ratio testing with point-of-care coagulometer in healthy term neonates
نویسندگان
چکیده
BACKGROUND Neonates routinely receive vitamin K to prevent vitamin K deficiency bleeding, which is associated with a high mortality rate and a high frequency of neurological sequelae. A coagulation screening test might be necessary to detect prophylactic failure or incomplete prophylaxis. However, venous access and the volume of blood required for such testing can be problematic. CoaguChek XS is a portable device designed to monitor prothrombin time while only drawing a small volume of blood. Although the device is used in adults and children, studies have not been performed to evaluate its clinical utility in neonates, and the reference value is unknown in this population. The objectives of the present study were to determine the reference intervals (RIs) for international normalized ratio (INR) using the CoaguChek XS by capillary puncture in healthy term neonates, to evaluate factors that correlate with INR, and to evaluate the device by assessing its ease of use in clinical practice. METHODS This study included 488 healthy term neonates born at a perinatal center between July 2012 and June 2013. The INRs determined by CoaguChek XS were measured in 4-day-old neonates. RESULTS The enrolled neonates were orally administered vitamin K 6-12 h after birth. A RI for INRs in 4-day-old neonates was established using the CoaguChek XS with a median value of 1.10 and a range of 0.90-1.30. A significant difference in the INR was noted between male (median value, 1.10; RI, 0.90-1.30) and female (median value, 1.10; RI, 0.90-1.24) neonates (p = 0.049). The INR was found to correlate with gestational age, birth weight, and hematocrit value. CONCLUSIONS The CoaguChek XS device is safe, fast, and convenient for performing INR assays in neonates. Our study is the first to establish a RI for INRs that were measured using the CoaguChek XS in healthy term neonates.
منابع مشابه
Factors determining patients’ intentions to use point-of-care testing medical devices for self-monitoring: the case of international normalized ratio self-testing
PURPOSE To identify factors that determine patients' intentions to use point-of-care medical devices, ie, portable coagulometer devices for self-testing of the international normalized ratio (INR) required for ongoing monitoring of blood-coagulation intensity among patients on long-term oral anticoagulation therapy with vitamin K antagonists, eg, warfarin. METHODS A cross-sectional study that...
متن کاملClinical Utility and Accuracy of Coaguchek XS, a Reliable Alternative to Laboratory International Normalized Ratio Monitoring in Korean Patients With Atrial Fibrillation
Background and Objectives: To evaluate the accuracy and the clinical utility of the Coaguchek XS, a portable point-of-care coagulometer, compared to standard laboratory methods in Korean patients. Subjects and Methods: We included 107 patients with atrial fibrillation on long-term oral warfarin therapy. The prothrombin time as expressed by the international normalized ratio (INR) was measured b...
متن کاملValidation of the CoaguChek XS international normalised ratio point-of-care analyser in patients at Charlotte Maxeke Johannesburg Academic Hospital, South Africa.
BACKGROUND Measurement of the international normalised ratio (INR) is essential in the management of patients on long-term warfarin therapy. The CoaguChek XS portable coagulometer is a point-of-care test for INR measurement. It offers the advantage of improved patient accessibility, particularly in peripheral clinics. OBJECTIVES To evaluate the clinical utility of the CoaguChek XS for monitor...
متن کاملPoint of care coagulometry in prehospital emergency care: an observational study
BACKGROUND Haemostatic impairment can have a crucial impact on the outcome of emergency patients, especially in cases of concomitant antithrombotic drug treatment. In this prospective observational study we used a point of care (POC) coagulometer in a prehospital physician-based emergency medical system in order to test its validity and potential value in the treatment of emergency patients. ...
متن کاملSeasonal variation in the international normalized ratio of neonates and its relationship with ambient temperature
BACKGROUND The morbidity and mortality rates due to cardiovascular events such as myocardial infarction are known to exhibit seasonal variations. Moreover, changes in the ambient temperature are reportedly associated with an increase in these events, which may potentially involve blood coagulation markers. Bleeding due to vitamin K deficiency in neonates, which is associated with high mortality...
متن کامل