OBJECTIVES The aim is to define conditions for exact measurement of urethral pressure profile, to prepare an aparatus and fabricate an artificial urethra for testing measuring catethers. To examine it's qualities by experiment. METHODS We designed a measuring appliance and a specialized software for measuring and evaluating. An experimental phantom of urethra, made from a part of bull's urethra, was used for testing of measurement's validity with use of different measuring catethers. Measurements were 10x repeated within the same position of the catether. Reproducibility of the measurement and stability of the experimental model was tested. RESULTS Measuring urethra and experimental phantom of urethra succeeded, it was possible to make well reproducible measurements with different measuring catethers and to evaluate their metrologic abilities and limits. Results of our measurements confirmed appointed theoretical conditions of the measurement. CONCLUSION Measurements proved that it is possible to simulate the conditions that are similar to physiological conditions and that it is possible to test metrological qualities of compressive profilometry of urethra.
منابع مشابه
Signal processing in urodynamics: towards high definition urethral pressure profilometry
BACKGROUND Urethral pressure profilometry (UPP) is used in the diagnosis of stress urinary incontinence (SUI) which is a significant medical, social, and economic problem. Low spatial pressure resolution, common occurrence of artifacts, and uncertainties in data location limit the diagnostic value of UPP. To overcome these limitations, high definition urethral pressure profilometry (HD-UPP) com...
متن کاملMeasurement of urethral closure function in women with stress urinary incontinence.
PURPOSE We assessed the use of urethral pressure reflectometry in detecting pressure increases in the female urethra and compared the usefulness of urethral pressure reflectometry vs urethral pressure profilometry in a pharmacodynamic intervention study. MATERIALS AND METHODS In this randomized, double-blind, placebo controlled, crossover study 17 women with stress urinary incontinence or mix...
متن کاملMaximum urethral closure pressure and sphincter volume in women with urinary retention.
PURPOSE In 1988 a syndrome of isolated urinary retention in young women that is associated with electromyographic abnormality of the striated urethral sphincter was described. It was hypothesised that urinary retention resulted from a failure of sphincter relaxation. The electromyographic abnormality causes overactivity of the muscle and may induce changes of work hypertrophy. If the hypothesis...
متن کاملIs a sequence of tests during urethral pressure profilometry correlated with symptoms assessment in women?
INTRODUCTION Our purpose was, applying a strictly defined protocol for urethral profilometry, 1) to test the repeatability of same session rest maximum urethral closure pressure (MUCP) and 2) to search for correlation between women complaint and the changes in MUCP value (rest and dynamic tests). MATERIALS AND METHODS A population of 140 consecutive women referred for evaluation of lower urin...
متن کاملVerification of a CFD solver in near ground effect for aerodynamic behavior of airfoil NACA 0015
Numerical investigation was performed on NACA 0015 which is a symmetric airfoil. Pressure distribution and then lift and drag forces are verified. Changing of ground clearance was a considerable point. Also the angle of attack was changed from 0° to 10°. Pressure coefficient reaches its higher amounts on the wing lower surface when the ground clearance diminishes. Increment of the angle of atta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia
دوره 150 2 شماره
صفحات -
تاریخ انتشار 2006