A method to improve the accuracy of continuous measuring of vertical profiles of temperature and water vapor density by means of a ground-based microwave radiometer
نویسندگان
چکیده
Article history: Received 8 August 2012 Received in revised form 20 September 2012 Accepted 9 October 2012 Available online 3 November 2012 Many of the meteorological phenomena occurring at meso-γ require observations sufficiently close together in time and space. The multichannel microwave radiometer (MMWR) provides continuous temperature and humidity profiles. We demonstrate a method for profile bias correction that significantly improves vertical temperature (T) and water vapor density (δwv) profile accuracy. We compared MMWR temperature (TRD) and humidity (δwvRD) profiles during winter in the Sierra of Guadarrama (Madrid) at 1150 m altitude with thousands of radiosonde temperature (TRW) and humidity (δwvRW) soundings from a launch site at 610 m altitude and 50 km distance. In spite of relatively large horizontal and vertical separation between the two sites, sounding differences above the boundary layer are comparable to observation error typically assigned to radiosonde soundings when they are assimilated into numerical weather models. Systematic bias between the paired values of TRW and TRD and δwvRW and δwvRD ranges from 0.2 to 1.2 K and 0.05 to 0.5 g m−3. This bias can be removed using a corrector function that is applied at each T and δwv level. Using this method, the bias for both variables is reduced to insignificant levels and their accuracy is significantly improved. © 2012 Elsevier B.V. All rights reserved.
منابع مشابه
Development and Calibration of a K-band Ground-based Hyperspectral Microwave Ra- Diometer for Water Vapor Measurements
In this paper, a K-band ground-based hyperspectral microwave radiometer for atmospheric sounding is proposed, which improves the profile error and vertical resolution of moisture profiling under the high water vapor condition. The hyperspectral microwave radiometer (80 K-band spectral channels) can observe the rapidly changing weather with high sensitivity and accuracy of brightness temperature...
متن کاملPassive ground-based remote sensing of atmospheric temperature, water vapor, and cloud liquid water profiles by a frequency synthesized microwave radiometer
Summar . An advanced microwave radiometer for profiling atmospheric parameters is described in this paper. The method accomplishing profiling is described. The innovations of the radiometer system, including utilization of a stable frequency synthesizer and the calibration system are described. The performance of several mathematical retrieval methods and representative profiles are presented, ...
متن کاملThe accuracy of water vapor and cloud liquid determination by dual-frequency ground-based microwave radiometry
A dual frequency ground-based radiometer operating in the 1 to 1.4 cm wavelength range can provide continuous measurements of integrated water vapor and cloud liquid water. Using climatological data, the accuracy of the vapor and liquid determinations is estimated as a function of cloud amount. Limiting factors in the water determination are uncertainties in water vapor absorption coefficients ...
متن کاملMicrowave radiometric technique to retrieve vapor, liquid and ice. I. Development of a neural network-based inversion method
With the advent of the microwave radiometer, passive remote sensing of clouds and precipitation has become an indispensable tool in a variety of meteorological and oceanographical applications. There is wide interest in the quantitative retrieval of water vapor, cloud liquid, and ice using brightness temperature observations in scientific studies such as earth’s radiation budget and microphysic...
متن کاملRadiometric profiling of temperature, water vapor and cloud liquid water using various inversion methods
We have developed a tunable temperature profiler based on a highly stable synthesizer that can observe at multiple frequencies on the shoulder of the 60 GHz atmospheric oxygen feature. We are developing a similar radiometer to obtain the vertical distribution of water vapor by making observations on the pressure broadened water vapor line from 22 to 29 GHz. Information on cloud liquid water pro...
متن کامل