Adhesive bonding of resin composite to various titanium surfaces using different metal conditioners and a surface modification system

نویسندگان

  • Hercules Jorge ALMILHATTI
  • Karin Hermana NEPPELENBROEK
  • Carlos Eduardo VERGANI
  • Ana Lúcia MACHADO
  • Ana Cláudia PAVARINA
  • Eunice Teresinha GIAMPAOLO
چکیده

OBJECTIVE This study evaluated the effect of three metal conditioners on the shear bond strength (SBS) of a prosthetic composite material to cpTi grade I having three surface treatments. MATERIAL AND METHODS One hundred sixty eight rivet-shaped specimens (8.0x2.0 mm) were cast and subjected to polishing (P) or sandblasting with either 50 mm (50SB) or 250 mm (250SB) Al2O3. The metal conditioners Metal Photo Primer (MPP), Cesead II Opaque Primer (OP), Targis Link (TL), and one surface modification system Siloc (S), were applied to the specimen surfaces, which were covered with four 1-mm thick layers of resin composite. The resin layers were exposed to curing light for 90 s separately. Seven specimens from each experimental group were stored in water at 37ºC for 24 h while the other 7 specimens were subjected to 5,000 thermal cycles consisting of water baths at 4ºC and 60ºC (n=7). All specimens were subjected to SBS test (0.5 mm/min) until failure occurred, and further 28 specimens were analyzed using scanning electron microscope (SEM) and X-ray energy-dispersive spectroscopy (EDS). Data were analyzed by 3-way ANOVA followed by post-hoc Tukey's test (α=0.05). RESULTS On 50SB surfaces, OP groups showed higher SBS means than MPP (P<0.05), while no significant difference was found among OP, S, and TL groups. On 250SB surfaces, OP and TL groups exhibited higher SBS than MPP and S (P<0.05). No significant difference in SBS was found between OP and TL groups nor between MPP and S groups. The use of conditioners on 250SB surfaces resulted in higher SBS means than the use of the same products on 50SB surfaces (P<0.05). CONCLUSION Sandblasting associated with the use of metal conditioners improves SBS of resin composites to cpTi.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Shear Bond Strength of Composite Restorations to Intact Enamel of Primary Incisors When Using Different Conditioners and Adhesive Systems

Introdouction: Esthetic demands of patients have led to the introduction of tooth-colored restorations wherecomposite resins are bonded to the enamel using acid etch techniques. Total etch adhesion systems are still considered as the gold standard among bonding systems. However, clinicians have a tendency to use adhesive systems with simpler application procedures. The aim of the present stu...

متن کامل

Evaluation of microtensile bond strength of repaired dental resin composite using different surface treatment techniques: A laboratory study

Background and Aims: Today, resin composites are one of the most commonly used materials in restorative dentistry. However, failure in resin treatments is also common due to its chemical nature and its high talent for decay recurrence. According to conservative approaches, "conservative" treatments are more likely to be considered than "Replacement" of damaged remedies. The purpose of this stud...

متن کامل

Effect of Type of Surface Treatment and Adhesive System on Shear Bond Strength of Composite Resin to a Non-Precious Metal Alloy

Background and Aim: Fractured metal-ceramic restorations may be repaired with composite in some cases to postpone the fabrication of a new restoration. Knowledge about the bond strength can help predict the success rate of this treatment modality. The aim of this study was to assess the effect of two types of mechanical surface treatment of metal along with the use of different adhesive systems...

متن کامل

Shear bond strength evaluation of resin composite to resin-modified glass-ionomer cement using three different resin adhesives vs. glass-ionomer based adhesive

Background: The clinical success of sandwich technique depends on the strength of resin-modified glass ionomer cement (RMGIC) bonding to both dentin and resin composite. Therefore, the shear bond strength (SBS) of resin composite bonded to RMGIC utilizing different resin adhesives versus a GIC-based adhesive was compared. Materials and methods: In this in vitro study, 84 holes (5×2 mm) were pre...

متن کامل

Evaluation of the effect of two different desensitizing agents on shear bond strength of universal adhesive resin (an invitro study )

Background and Aim: dentin desensitizers may affect dentin organic matrix properties or occlude dentinal tubules which may have adverse effects on the bonding performance of adhesive systems. The aim of this study was invitro evaluation of Gluma desensitizer and Tokuyama Shield Plus effects or shear bond strength of (BISCO) all-bond universal bonding  system. Materials and Methods: 30 caries f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2013