Complications in the management of closed high-energy proximal tibial plateau fractures
نویسندگان
چکیده
PURPOSE To report complications in the management of complex closed proximal tibial fractures. METHOD A retrospective study was conducted to analyze the infectious and noninfectious complications encountered in the management of high-energy Schatzker type V and VI tibial plateau fractures. All patients were treated at the level 1 trauma centre between January 2011 and March 2014. Sixty two patients were included in the study. The mean patient age was (43.16 ± 11.59) years with 60 males and 2 females. Infectious complications like superficial and deep infection, wound dehiscence, malalignment in the immediate postoperative period and in follow-up period were noted. RESULTS The overall complication rate was 30.65% (19 out of 62). Infectious complications were noted in 20.97% cases (13/62). In majority of the cases (8/13), superficial infection was seen which managed with regular dressing and antibiotic administration. The patients (5/13) who had developed deep-seated infection were subjected to repeated debridements, flap coverage, implant removal or amputation depending upon the host response. Thirteen patients had experienced noninfectious complications. Hardware related complications were noticed in six patients and four among them received a secondary procedure. Malalignment was observed in seven patients but only single patient underwent subsequent operative intervention. CONCLUSION Proximal tibial plateau fractures especially Shatzker type V and VI are associated with extensive soft tissue damage even in closed injuries. The complications encountered in the management of these fractures can be minimized with appropriate patient selection and minimal soft tissue dissection.
منابع مشابه
Preoperative planning of proximal tibial fractures
Historically open reduction and internal !xation of high energy proximal tibia fractures have been associated with high rates of infection (13–88%) and nowadays staged protocol for management was proposed (1). Also articular step o"s and angular deformities after operative treatment are observed in 10–19% of cases (2). Taking all this into account the complex tibial plateau fractures management...
متن کاملHigh energy tibial plateau fractures treated with hybrid external fixation
Management of high energy intra-articular fractures of the proximal tibia, associated with marked soft-tissue trauma, can be challenging, requiring the combination of accurate reduction and minimal invasive techniques. The purpose of this study was to evaluate whether minimal intervention and hybrid external fixation of such fractures using the Orthofix system provide an acceptable treatment ou...
متن کاملOutcomes of the isolated closed tibial shaft fractures treated nonsurgically
Abstract Background: Fractures of the tibia are important for their commonness and controversy in their management. Both conservative and surgical techniques have been introduced in an effort to speed time to :::union::: while minimizing the occurrence of complications. Standard treatment for low-energy tibial shaft fractures includes closed reduction and cast immobilization. The purpose of...
متن کاملArthroscopic management of proximal tibial fractures: technical note and case series presentation
BACKGROUND AND AIMS The purpose of this article is to describe a new surgical method of arthroscopy assisted treatment of intraarticular proximal tibial fractures (ARIF - arthroscopic reduction and internal fixation), analyzing its efficiency and safety on a series of patients. Tibial plateau fractures affect the proximal tibial metaphyseal and articular surface, representing 1.2% of all fractu...
متن کاملModified hybrid fixator for high-energy Schatzker V and VI tibial plateau fractures
High-energy tibial plateau fractures associated with severe soft tissue injury are difficult to manage. The risk of wound complications following open reduction and internal fixation is notably high owing to extensive soft tissue dissection. Alternatively, application of hybrid external fixator minimizes soft tissue dissection and provides adequate fracture stabilization to allow early range of...
متن کامل