Anatomic distribution of gadolinium contrast medium by high-resolution magnetic resonance imaging after peribulbar and retrobulbar injections.

نویسندگان

  • David R P Almeida
  • Michel J Belliveau
  • Thomas Enright
  • Omar Islam
  • Sherif R El-Defrawy
  • Jeffrey Gale
چکیده

OBJECTIVE To examine the anatomic distribution of gadolinium contrast medium by high-resolution surface-coil magnetic resonance imaging after peribulbar and retrobulbar injection. METHODS Comparative case series in which 4 healthy volunteers were randomized to peribulbar (n = 2) or retrobulbar (n = 2) injection of gadolinium and lidocaine hydrochloride, 2%, without epinephrine. Magnetic resonance imaging was performed before injection and at 5 minutes and 90 minutes after injection. RESULTS The peribulbar injection technique resulted in contrast medium primarily in the extraconal space, with no gadolinium observed at the orbital apex; surprisingly, a small amount of contrast medium was observed in the pterygopalatine fossa immediately after peribulbar injection. The retrobulbar injection technique resulted in gadolinium signal diffusely enhancing the intraconal space, orbital apex, optic nerve sheath, and optic canal. The signal intensity was clearly observed in the cavernous sinus surrounding the cavernous portion of the internal carotid artery. A small amount of contrast medium was detected in the pterygopalatine fossa. CONCLUSIONS The retrobulbar injection technique localizes to the intraconal space, with access to intracranial and central nervous system structures via the optic canal, superior orbital fissure, and cavernous sinus. In contrast, the peribulbar injection technique produces a mostly extraconal distribution; however, intraconal solution may communicate with the central nervous system via the inferior orbital fissure and pterygopalatine fossa. This novel finding suggests that peribulbar anesthesia has a readily accessible route for central nervous system toxic effects. Magnetic resonance imaging with gadolinium contrast medium administration provides an important methodological advantage over previously described techniques and is a safe, reproducible, and superior method of orbital imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gadolinium-Diethylenetriaminepenta-Acetic acid Conjugated with Monoclonal Antibody C595 as New Magnetic Resonance Imaging Contrast Agents for Breast Cancer (MCF-7) Detection

Background: The monoclonal antibody, C595, against breast cancer cell line was conjugated with cyclic anhydride gadolinium-diethylenetriaminepenta-acetic acid (Gd-cDTPAa) to produce Gd-DTPA-C595 and used as specific breast cancer cell line (MCF-7) contrast agents in magnetic resonance imaging (MRI).  Methods: After incubation of breast cancer cell line (MCF-7), with different contrast agents (G...

متن کامل

Synthesis and biological evaluation of a novel Glucosylated Derivative of Gadolinium Diethylenetriaminepentaacetic acid for Tumor Magnetic Resonance Imaging

Cancer detection in early stage using a powerful and noninvasive tool is of high global interest. In this experiment, a small-molecular-weight glucose based derivative of Gd3+-1-(4-isothiocyanatobenzyl) diethylene tri amine penta acetic acid (Gd3+-p-SCN-Bn‐DTPA‐DG) as a novel potential MR imaging contrast agents was synthesized. Gd3+-p-SCN-Bn‐DTPA‐DG was synthesized with reacting of Glucosamine...

متن کامل

Synthesis and biological evaluation of a novel Glucosylated Derivative of Gadolinium Diethylenetriaminepentaacetic acid for Tumor Magnetic Resonance Imaging

Cancer detection in early stage using a powerful and noninvasive tool is of high global interest. In this experiment, a small-molecular-weight glucose based derivative of Gd3+-1-(4-isothiocyanatobenzyl) diethylene tri amine penta acetic acid (Gd3+-p-SCN-Bn‐DTPA‐DG) as a novel potential MR imaging contrast agents was synthesized. Gd3+-p-SCN-Bn‐DTPA‐DG was synthesized with reacting of Glucosamine...

متن کامل

Synthesis and Application of New Gadolinium-Porphyrins as Potential MR Imaging Contrast Agents for Cancer Detection in Nude Mice

Two new potential magnetic resonance imaging contrast agents, Gd-hematoporphyrin (Gd-H) and Gd-tetra-carboranylmethoxyphenyl-porphyrin (Gd TCP), were synthesized and applied to nude mice with human melanoma (MM 138) xenografts. These agents showed a high relaxivity because of their greater potential to coordinate water molecules. The reduction of T1 relaxation times of 16 and 21% was observed i...

متن کامل

The Assessment of Toxicity Characteristics of Cellular Uptake of Paramagnetic Nanoparticles as a New Magnetic Resonance Imaging Contrast Agent

Nanoparticles are unique that enable many promising medical and technological applications intheir physical, and chemical properties. It is widely accepted that nanoparticles should bethoroughly tested for health nanotoxicity, but a moderate risk analysis is currently prevented by arevealing absence of mechanistic knowledge of nanoparticle toxicity. The purpose of this study<b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 130 6  شماره 

صفحات  -

تاریخ انتشار 2012